CONNECTING YOUR EQUIPMENT

 

Plug the mission critical equipment into the Battery Backup & Surge output 
receptacles on the top panel of the UPS.  Plug the noncritical equipment into 
the Surge Only output receptacles on the top panel of the UPS.    Ensure that the 
connected equipment does not exceed the maximum output rating of the UPS 
(refer to the information label on the UPS or the electrical specifications in this 
manual).  DO NOT PLUG EXTENSION CORDS, ADAPTER PLUGS, SURGE 
STRIPS OR POWER STRIPS INTO THE OUTPUT RECEPTACLES OF THE 
UPS, there is a risk of damaging the UPS and/or connected equipment.  

CAUTION!  DO NOT

 connect a laser printer, copier, vacuum cleaner, or any 

other large electrical device into the output of the UPS. 
 

CONNEXION DE L'ÉQUIPEMENT

 

Branchez l'équipement essentiel sur les prises de sortie Battery Backup & Surge 
(secours batterie et surtension) qui se trouvent au panneau supérieur de 
l'onduleur. Branchez l'équipement non essentiel sur les prises de sortie Surge 
Only (uniquement surtension) au panneau supérieur de l'onduleur. Vérifiez que 
l'équipement connecté ne dépasse pas la puissance de sortie maximale de 
l'onduleur (lisez l'étiquette d'information sur l'onduleur ou les spécifications 
électriques dans ce manuel). NE BRANCHEZ PAS DE CORDES D'EXTENSION, 
DE FICHES D'ADAPTATEUR, DE BANDES DE SURTENSION OU DE 
BARRES MULTIPRISES DANS LES PRISES DE SORTIE DE L'ONDULEUR, 

13 

au risque d'endommager l'onduleur ou l'équipement connecté. 

MISE EN 

GARDE! ÉVITEZ

 de connecter une imprimante laser, une photocopieuse, un 

aspirateur ou tout autre appareil électrique de grande taille à la prise de sortie de 
l'onduleur. 
 

CONNECTING THE UPS TO AN AC SOURCE

   

CAUTION!

  To reduce the risk of fire, connect only to a utility powered circuit 

with 20 amperes maximum branch circuit over-current protection in accordance 
with the National Electric Code, ANSI/NFPA 70.    Plug the UPS into a two pole, 
three wire, grounded receptacle only.   

The utility powered AC wall outlet that 

supplies the UPS shall be installed near the UPS and shall be easily 
accessible.

    DO NOT PLUG THE UPS INTO EXTENSION CORDS, ADAPTER 

PLUGS, SURGE STRIPS OR POWER STRIPS. DO NOT CUT THE INPUT 
PLUG OFF AND ATTEMPT TO HARDWIRE THIS UPS; DOING SO WILL VOID 
THE WARRANTY. 
 

CONNEXION DE L’ONDULEUR À UNE SOURCE CA

 

MISE EN GARDE!

    Pour réduire les risques d’incendie, raccordez uniquement 

sur un circuit d'alimentation électrique alimenté par le service public et doté d'un 
dispositif de protection contre les surintensités du circuit de dérivation de 20 
ampères maximum, conformément au Code national de l'électricité, ANSI/NFPA 
70. Branchez l’onduleur uniquement sur une prise bipolaire à trois fils mise à la 
terre. La prise murale CA alimentant l'onduleur doit être installée à proximité de 
l'onduleur et être facilement accessible. NE BRANCHEZ PAS L’ONDULEUR 
SUR UNE RALLONGE, UN ADAPTATEUR, UN LIMITEUR DE SURTENSION 
OU UNE BARRE MULTIPRISES. NE COUPEZ JAMAIS LA FICHE D’ENTRÉE 
POUR TENTER DE CÂBLER CET ONDULEUR; CECI ANNULERA LA 
GARANTIE. 
 

CHARGING THE BATTERY

 

The UPS will charge the internal batteries whenever the UPS is connected to an 
AC source and there is an acceptable AC voltage present (95 - 140VAC).    It is 
recommended that the UPS's batteries be charged for a minimum of 4 hours 
before use.  The UPS may be used immediately; however, the “On Battery” 
runtime may be less than normally expected.    Typical battery life is 3 to 5 years.   
Environmental factors do affect battery life.  High temperatures, poor utility 
power, and frequent, short duration discharges have a negative impact on 
battery life.    If the UPS is going to be out of service or stored for a prolonged 
period, the batteries must be recharged for at least twenty-four hours every 
ninety days. 

 

CHECKING THE SITE WIRING FAULT

 

After plugging the UPS into the AC wall outlet, check for the Site Wiring Fault.   
If the Warning / Fault (Red) LED is on and all the other LEDs are off, the UPS is 
plugged into an improperly wired AC wall outlet.  Have a qualified Electrician 
correct the problem. 

 
 

Summary of Contents for Minuteman Enspire Series

Page 1: ...ystems Inc 1455 LeMay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000552 R1 Enspire Series UPS EN450G EN600GU EN750G User s M...

Page 2: ...roduction 2 2 Controls and Indicators 8 3 Installation 10 4 Operation 14 5 Obtaining Service 18 6 Troubleshooting 19 7 Replacing the Battery 20 8 Specifications 30 9 Limited product Warranty 32 A1 Dec...

Page 3: ...er ou de les couvrir afin de garantir un fonctionnement fiable de l onduleur et de le prot ger contre la surchauffe N introduisez aucun objet dans les vents ou les ouvertures qui pourrait g ner la ven...

Page 4: ...ING Qualified Service Personnel ONLY must perform the Installation and Servicing of these UPS systems MINUTEMAN accepts no liabilities and is not limited to injury to the Service Personnel or damages...

Page 5: ...a partie responsable de la conformit peuvent annuler le droit de l utilisateur utiliser l quipement 7 NOTE These UPSs are shipped with the batteries disconnected The batteries must be connected before...

Page 6: ...when the UPS is operating in the Battery mode The On Battery Yellow LED will turn on when the UPS is operating in the Battery mode and will turn off when the UPS is operating in the AC normal mode Th...

Page 7: ...read the installation placement and all the cautions before installing the UPS Place the UPS in the final desired location and complete the rest of the installation procedure These UPSs are shipped w...

Page 8: ...the UPS into a two pole three wire grounded receptacle only The utility powered AC wall outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible DO NOT PLUG THE UPS...

Page 9: ...m systems VoIP systems security systems and a variety of electronic equipment from blackouts brownouts over voltages and surges During normal AC operation the UPS will quietly and confidently protect...

Page 10: ...e normal AC mode the alarm will stop the On Battery LED will turn off and the AC normal LED will turn on LOW BATTERY WARNING When the batteries reach the predetermined level the Warning Fault LED will...

Page 11: ...original sales receipt and a brief description of the problem 5 Mark the RMA on the outside of all packages The factory cannot accept any package without the RMA marked on the outside of the package...

Page 12: ...caux pour savoir comment correctement liminer une batterie ou renvoyez la au fournisseur CAUTION The battery system can present a risk of electrical shock These batteries produce enough current to bur...

Page 13: ...DO NOT pull the battery module out by pulling on the battery wires 8 Disconnect the battery positive Red wire FIG 3 9 Disconnect the battery negative Black wire and set the old battery module aside FI...

Page 14: ...la de c t FIG 2 ATTENTION NE retirez PAS la batterie en tirant sur les fils de la batterie 8 D branchez le fil positif de la batterie rouge FIG 3 9 D branchez le fil n gatif de la batterie noir et me...

Page 15: ...e battery module out by pulling on the battery wires 8 Disconnect the battery negative Black wire FIG 3 9 Disconnect the battery positive Red wire and set the old battery module aside Do not short the...

Page 16: ...ers le haut FIG 2 NE retirez PAS la batterie en tirant sur les fils de la batterie 8 D branchez le fil n gatif de la batterie noir FIG 3 9 D branchez le fil positif de la batterie rouge et mettez de c...

Page 17: ...Regulated Lead Acid Typical Recharge Time 8 hours to 90 capacity from a full load discharge Typical Battery Life 3 to 5 years Environmental factors do affect battery life High temperatures poor utilit...

Page 18: ...ESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation of implied warranties therefore the aforesaid limitation s may not ap...

Page 19: ...34 Notes 35 Notes...

Reviews: