Stage Projector
BP 4 CT
Pani Projection and Lighting Vertriebs GmbH
15
7) Electrical Connection
(See Electrical Schematic 230- 02- 01/a)
The HMI Stage Projector BP 4 CT is used in conjunction with the ballast 4000 W,
220/240V- 50 Hz, 208/220V- 60 Hz (Order Code: 19203).
The ballast incorporates a choke which limits lamp power to 24 A.
Main power is interrupted when the projector housing is opened.
7.1) Main Power Connection
Universal - ballast 4000 W, 220/240 V- 50 Hz, 208/ 220 V- 60 Hz
Main Power Cable 3x 4 square millimeters, two meters long with open leads
Phase R: brown, Neutral N: blue, Ground PE: yellow/green
Connected to power source 230 V/ 50 Hz, 25 A
7.2) Connecting Cable Ballast - Projector
On the Universal - ballast there is one lamp current cable mounted with a CEE -
clutch 4x 32 A and one remote cable with a 10-pin clutch. Standardlength is 3 m
(may be extended – for extremely long runs wire gauge may need to be larger). Both
cables are connected to the projector by using the mounted plugs.
The "ON" and the "OFF“ function can be performed at either the ballast or the
projector. Thus, it is possible to locate the ballast away from the projector.
7.3) Remote Ignition - DMX 512
For ignition and shut down of the projector by a DMX 512 signal, a relay card and
associated DMX In connector are located on the projector (Ignition Pos. 8). In
addition the optional Universal DMX 512 interface and the corresponding ignition
cable are necessary (for further information see the instruction manual of the
Universal DMX 512 Interface).
POSITION NUMBERS SEE PAGE 6