Stage Projector
BP 4 CT
Pani Projection and Lighting Vertriebs GmbH
14
5.4) Using the Tilt Angle Meter
For safe operation it is necessary to respect the tilt
range of the projector (see General Technical Data
on page 21).
Use the delivered Tilt Angle Meter by applying it on
the top edge of the projector (before operation). The
red locator indicates the actual tilt angle.
6) Position Drawing Condenser System
Legend
Type:
Order Code:
(1)
Spherical Cold Mirror 165 mm Ø
100-15-19
(2)
HMI- Lamp 4000 W single ended
37206
(3)
Meniscus Lens Ø 147 mm
222- 03- 05
(4)
Middle Condenser Lens PC Ø 220 mm/ R 156 Borosilikat
(5)
PANI – Universal Filter
Ø 220 x 4
(6) Front Condenser Lens for Objective 11- 27 cm,
PC Ø 230 mm, multicoated, with Mounting Plate
12440
Front Condenser Lens for Objective 33- 40 cm,
PC Ø 230 mm, multicoated, with Mounting Plate
12441
Front Condenser Lens for Objective 50- 60cm,
PC Ø 230 mm, multicoated, with Mounting Plate
12442
Front Condenser Lens for Objective 80 -125 cm,
PC Ø 230 mm, multicoated, with Mounting Plate
12443