![Panduit PES400 Operation Manual Download Page 48](http://html2.mh-extra.com/html/panduit/pes400/pes400_operation-manual_3469203048.webp)
© Panduit Corp. 2018
OPERATION MANUAL
PES400
ENGLISH
PES400: PA28981A01_01
Page: 46 of 46
4-2018
SENSORS
Sensors should be cleaned with alcohol swabs. These are
normally readily available, or you can provide your own. We
recommend a 91% or higher concentration of lsopropyl Alcohol.
Use a thicker cloth, or towel to reduce the amount of particulate
left on sensors after cleaning
PUNCH LEVER
•
To access the Punch Lever,
you will need to remove the
access plate in blue with a
3mm Hex/Allen key.
•
After doing this an inspection
should be done on the Lever
mechanism. If excessive
debris is present clean and re-
grease component.
•
Inspection should also be
done on the Bottom Punch
Lever as well.
After cleaning the PES400, it's recommended to run the machine anywhere from 25 to 100 full cycles
to properly distribute lubricant.
9. CONTACT INFORMATION • For Technical Support:
USA & Canada:
1-866-871-4571
Latin America:
+52-33-3777-6000
Europe:
+31-546-580-452
Asia Pacific Region:
65-6305-7575
Japan:
81-3-6863-6060
Australia: