APPENDIX A – SSR Error Messages
WARNING: Error codes below 64 are displayed as critical system error messages, and SSR
operation will be halted.
E31
Memory DDR failure
E32
Memory Queue error
E33
444 not supported in LP mode
E34
Mixed Memory board sizes
E35
Overtemp - Memory shutdown
E31 and E32 are hardware failures and the SSR should be returned to Panavision for service.
E33 indicates the SSR is in LP mode and has been asked to operate in the 444 format, this can
be cleared by changing the camera format to 422.
E34 indicates a configuration error with the memory hardware.
E35 indicates an over heating. Note that the E35 shut down is preceded by 2 earlier HOME
screen warnings: WARM (in yellow), then HOT (in red).
The following error codes are less serious but should not be ignored. You will be able to continue
recording. Contact your Panavision representative if you get any these errors. Operation should
be stopped if these error codes persist.
E64
System int error
E65
System file load error
E66
System file save error
E121
Clip list error
E130
Fan failure
The following error codes can safely be ignored but should be reported to Panavision if persistent.
E100
Input Video Missing
E101
Link A Missing
E102
Link B Missing
E104
Input video lost during record
E105
Memory Status error
E106
Memory size was changed
E110
Input framerate error
E120
External framerate error
E140
Camera shutdown (shutdown was requested by the camera)
Example of System error 33.
This error can be resolved by
changing the camera
!
s format
to 422 mode.