28
8 Settings and Operations (continue)
※
1 For gouging selection function, please refer to
【
8.7 gouging function
】
※
2 For the cutting torch monitoring function, please refer to
【
8.6the cutting torch monitoring function
】
※
3The data listed here are used for 100PF. For 80pfthe cutting torch, setting option of 35, 60 and 80 are
available and the initial value is 80. For 60PF the cutting torch, setting option 35, 60, initial value 60.
※
4 For the setting of the lock key, please refer to
【
8.9 operation lock function
】
※
5 For pulse cutting setting, please refer to
【
10.5.3 pulse cutting
】
8.6 The cutting torch monitoring function
·
To prevent the cutting torch from reducing cutting capacity and burning loss caused by the overuse of
electrode and cutting tip, pre-warning function can be selected.
·
The monitoring of arc ignition number of times and actual cutting time is achievable. When one of
them reaches set warning value, warning contents can be displayed.
·
It can be selected on the submenu either stop the output of the machine or just display warning
information when machine detects that the usage of the electrode and cutting tip reaches service life.
No.
Setting
Setting items
Set unit Default
Descriptions
P10
Cutting torch
cable length
select
10,20,30
m
10
Select the length of the cable to be used.
By using the selection on the cable length and cutting torch , the recommended
gas pressure can be automaticaly changed according to the specifications of
the cutting torch.
P11
Cutting torch
select
35,60,80
,
100
35P,60P,80P
,
100P
A
100P
35, 60, 80 and 100 represents curved cutting torch, 35P, 60P, 80P and 100P
straight handled cutting torch.
For connection with robot cutting, please select straight handled cutting torch.
If select curved cutting torch was selected, signal from robot would not be
received.
If the ratings of selected cutting torch are within the rated specification of the
cutting machine, set upper limit value of current can be limited within the rated
specification of the selected cutting torch.
In addition, recommend gas pressure of the selected cutting torch can be
automaticaly changed according to the specifications, cutting torch cable
length.
P12
Setting for
operation lock
* 3
LoC
(
operation
lock
)
PCH
(
password
modification
)
—
—
The operations such as the modification on the cutting current setting value and
the value of submenu etc. can be locked. It can be enabled or disabled by using
password.
Duirng the lock operation, operation lock LED on operation area is lit.
The password being set before shipment is " 123 ".
P13
Pulse cutting
setting * 4
(oFF)
(on)
—
OFF
When pulse cutting ( P13 ) is set on " ( ON ) " status , pulse cutting function
is enabled.
When the gouging selection ( P01 ) is " ( ON ) " , even if pulse cutting ( P13 )
is set on " ( ON ) " status, this function is not valid.
P14 All reset
no
yes
—
no
When cutting condition and setting contents on submenu are to be restored to
factory settings, this function can be used.
After selecting ( yes ) , press confirmation button, untill ( off ) is displayed. Then
it is required to restart the power source.