8 Settings and Operations (continue)
8.5.3 The contents of submenu
No.
Setting
Setting items
Set unit Default
Descriptions
P01
Gouging
select * 1
OFF(oFF)
ON(on)
—
oFF
Place gouging selection ( P01 ) at " ( on ) " side to enable air plasma gouging.
P02
Cutting torch
mornitoring
select * 2
OFF(oFF)
ON(on)
RESET
(
rSt
)
—
on
When placing the cutting torch mornitoring selection ( P02 ) at " ( ON ) " side to
enable the machine to prevent the cutting torch from redecing cutting capacity
and burning loss caused by the overuse of electrode and cutting tip, pre-
warning function can be realized. When selection ( P02 ) at " ( OFF ) " side, the
remaining number of times, duration are kept. When " reset ( rSt ) " is selected
and confirmed, the remaining number of times, duration are reset.
P03 --
——
—
——
The function can't be used in the Product.
P04
Setting for
thecutting
torch number
of mornitoring
times * 2
off~999
1 time
200
The mornitoring of cutting torch on the number of arc ignition warning times can
be enabled. If the confirmation key is long-pressed, the remaining number of
times can be shown when pressing the confirmation key.
When gouging select ( P01 ) is at "( on )" side, the 5 times of number of
cuttings on cutting status is calculated.
When P02 is " ( off ) " , setting can be modified.
P05
Setting for
cutting torch
mornitoring
time * 2
off~200
1 min
90
The mornitoring of cutting torch on the alarming cutting time can be enabled. If
the confirmation key is long-pressed, the remaining duration can be shown when
pressing the confirmation key.
When gouging select ( P01 ) is at "( on )" side, the 5 times of cutting duration
on cutting status is calculated.
When P02 is " ( off ) " , setting can be modified.
P06
Setting for the
cutting torch
mornitoring
warning * 2
0
(
the cutting is
allowed even if
the alarming is
given.
)
1
(
the cutting is
not allowed
when the
alarming is
given.
)
—
1
The warning status of mornitoring of the cutting torch reaches the set number of
arc ignition times or cutting duration can be set.
P07
Self-hold
select
(oFF)
(on)
—
OFF
By setting the self-hold selection ( P07 ) to ( on ), self-hold of the cutting torch
switch can be realized.
①
during pre-flow ( 1 second )
②
during after-flow ( 20 second )
P08
-
—
—
—
The function can't be used in the Product.
P09
Recommend
range gas
pressure
warning
setting
0
(
the cutting is
allowed even if
the alarming is
given.
)
1
(
the cutting is
not allowed
when the
alarming is
given.
—
1
It can be set that warning is sent in case the input gas pressure is out of the
recommended range,
0 ( Cutting can be done after sending alarming. ) On setting status the gas
pressure, which is out of the recommended range, is used, the cutting
performance and the life span of the cutting torch parts may be reduced.
Cutting
torch
Self
-hold
Self-hold
[ON]
Self-hold
[OFF]
Air
Cutting
current
Air
Cutting
current