32
Configure the settings relating to the alarm image
Click the [Alarm] tab on the "Alarm" page. (
☞
pages 4 and 5: How to display/operate the setup menu)
■
Alarm image
The settings relating to the alarm image to be transmitted to an FTP server can be configured in this section. The
alarm image will be transmitted to an FTP server. To transmit alarm images to an FTP server, it is necessary to con-
figure the settings in advance. (
☞
page 43)
Refer to pages 31 and 34 for further information about the settings relating to the alarm and the alarm output termi-
nal.
Important:
• Depending on the network line speed or the network traffic, images may not be transmitted at the exact designat-
ed interval or period.
• When "Alarm input" or "Manual" is selected for "Save trigger" on the [SD memory card] tab, images will not be
transmitted to the FTP server even when an alarm is detected. (
☞
page 10)
When the configured image refresh interval is high, timing or interval of notification or recording may become
inexact and notification or recording may not carried out as configured when images are transmitted by multiple
users. (
☞
page 33) If this happened, set the image refresh interval lower.
• Timing of notification or saving of image file may sometimes take some time when the transmission interval is set
shorter or when multiple users are receiving images.
In this case, set the transmission interval longer.
[FTP >>]
When "FTP >>" is clicked, the [FTP img. trans.] tab of
the "Server" page will be displayed. (
☞
page 43)
[Alarm image FTP transmission]
Select "On" or "Off" to determine whether or not to
transmit the alarm image to the FTP server.
Default:
Off
[Directory name]
Enter the directory name where the alarm images are to
be saved.
For example, enter "/ALARM" to designate the directory
"ALARM" under the root directory of the FTP server.
Number of characters for the directory name:
1 - 256
characters
[File name]
Enter the file name used for the alarm image to be
transmitted to an FTP server. The file name will be as
follows.
File name:
["Entered file name" + "Time and date
(year/month/day/hour/minute/second)"] + "Serial
number"
Number of characters for the file name:
1 - 32 char-
acters
[Post alarm]
• Transmission interval
Select the transmission interval for the alarm image
transmission to the FTP server from the following.
0.1 fps/0.2 fps/0.33 fps/0.5 fps/1 fps
Default:
1 fps