Initialization of soft-
ware communica-
tion parameters
- 31 -
Precaution:
The following installations should be made by
qualified service personnel or system installers.
Setting the camera switches
(only for WV-CSR650)
• To reset the communication parameters to
the factory preset values, for example, when
operating multiple cameras in a daisy chain
connection, set the switches inside the
camera as shown in the table below.
1. Disassemble the camera
Confirm the power is turned off.
Remove the screw from inside the hole for
the fall prevention wire. Hold the diecast
case containing the camera and rotate it to
the left as shown below.
Note:
Setting of switches while the power is
on may cause a malfunction. Make sure
the power is turned off before setting
the switches.
Switch A: Full duplex (four lines)/Half duplex
(two lines) switch
Switch B: Termination ON/OFF switch
Switch C: Dip switches (become effective
when the power is turned on)
DIP 3
OFF
ON
Normal Setting
Initial
Settings
Camera Unit No.
DIP 1 DIP 2
OFF
OFF
01 - 32
OFF
ON
33 - 64
ON
OFF
65 - 96
ON
ON
Inhibition
Notes:
• Select OFF after resetting the parameters by
selecting ON.
• The factory settings is OFF.
Diecast Case
2.
Setting the switches
Set the switches as follows:
DIP
φ
ON
DIP Switches
OFF
DIP 1
DIP 2
DIP 3
Termination
ON
Half
(2 lines)
Switch A
Switch B
Full
(4 lines)
OFF
The factory settings for the dip switch 1 and 2
are OFF both.
INSTALLATION