- 10 -
SETTING PROCEDURES
The following setting procedures are described on the assumption that this model is used in combination
with the WJ-SX550A matrix switcher and WV-CU550A system controller. If used with the WV-RM70
camera controller, refer to “WV-RM70” on page 5 for operation.
■
Menu Display
●
Setup Menu Display
1. Select the number of the camera you want to set up and a monitor
to display the SET UP MENU.
2. Display the D4 menu on the LCD by pressing the appropriate
cursor buttons.
3. Press the F1 button.
The SET UP MENU appears on the monitor.
4. To close the SET UP MENU, press the F4 button.
Note:
Do not change the SET UP MENU (for camera communi-
cation) settings of the WV-CSR650 except CAMERA*. If those
settings are changed, the camera and the controller may get
out of control.
D4 menu
F 1
F 1
F 2
F 3
F 4
Camera Set Up Menu
Res A.Res Exit
F 2
F 3
F 4
Camera Set Up Menu
On Exit
*** SET UP MENU ***
CAMERA*
UNIT NUMBER 1
BAUD RATE 19200
DATA BIT 8
PARITY BIT NONE
XON/XOFF NOT USE
WAIT TIME OFF
ALARM DATA AUTO 2
DELAY TIME OFF
COM. SET UP DISABLE
Setup menu
for camera communication
(only for WV-CSR650)
*** SET UP MENU ***
PRESET 1*
MAP
HOME POSITION 15
SELF RETURN 10MIN
AUTO MODE AUTO PAN
FLIP-A-CHIP ON
LOCAL/REMOTE LOCAL
CAMERA
Setup menu
(for camera setting)
●
Submenu Display
The items marked
can be selected/changed on the submenu.
• Move the cursor to an item with the
mark and press the CAM
(SET) key. The submenu is displayed.
Note:
When you use the WV-CSR650, move the cursor to CAMERA
on the SET UP MENU for camera communication and press
the CAM (SET) key. The SET UP MENU for camera setting
appears in the display.
■
RS485 Set Up
●
Initial camera communication parameters
• Confirm the communication parameters of the matrix switcher (WJ-SX550A), and display the camera
SET UP MENU.
The initial camera communication parameters are shown in the illustration above.
The other parameters are as follows:
Daisy : OFF
Camera In Number : 1
F/H Duplex : Full