10
AUTO :
This setting, by moving the shutter automatical-
ly when necessary, provides a clearer picture
of extremely bright objects outdoors, etc.
OFF :
Fixed at 1/50 seconds.
The factory default setting is AUTO.
Notes:
• When AUTO is selected for the shutter setting,
fluorescent lighting may cause flickering of the
picture. If this happens, select OFF for the shutter
speed setting.
• AUTO is disabled when MANUAL is selected for
light control (ALC/MANUAL) and FIX is selected for
electronic sensitivity enhancement (SENS UP).
4
Gain Control (AGC)
1. Move the cursor to AGC, and then tilt the joystick
left or right to select a gain control setting.
ON (LOW) :
Low gain
ON (MID) :
Medium gain. This is the factory default
setting.
ON (HIGH) :
High gain
OFF
:
Does not increase the gain
Note:
• When AGC is turned on, the noise reduction
function automatically activates under low
illumination to reduce digital noise. This also,
however, can cause afterimages to be generated
by moving objects, and by panning and tilting the
camera. For more information, see the DNR
setting (page 11).
5
Electronic Sensitivity Enhancement (SENS UP)
1. Move the cursor to SENS UP, and then tilt the
joystick left or right to select an electronic sensitivity
enhancement setting.
The electronic sensitivity enhancement setting can
be changed only when OFF or AUTO is selected for
the shutter speed (SHUTTER) setting. Tilting the
joystick cycles through the settings display in the
sequence shown below.
When SUPER-D6
is turned off
When setting MANUAL of ALC/MANUAL
When SUPER-D6
is turned on
The factory default setting is OFF.
Use the following steps to perform masking
(1) Tilt the joystick up and down, and left and right
to move the cursor to a cell you want to mask.
(2) Press the CAM (SET) button to mask the cell.
Moving the cursor to a cell that is already
masked causes the blinking pattern of the
cursor to alternate between horizontal stripes
and white.
Pressing the CAM (SET) button while the cursor
is located at a masked cell cancels the masking
of the cell.
To cancel all masking areas, press the F3
button.
(3) After masking all of the cells you want, press the
MON (ESC) button to return to the ALC CONT
menu in step 1.
6. Move the cursor to LEVEL, and then tilt the joystick
left and right to adjust the picture output level
(picture contrast).
If you selected ON in step 3 of this procedure, best
results can be obtained by setting a contrast level
that is somewhat high. A contrast level that is too
high, however, may increase the tendency of
afterimages and noise.
3
Shutter Speed (SHUTTER)
1. Move the cursor to SHUTTER, and then tilt the
joystick left or right to select a shutter speed
setting.
Tilting the joystick cycles through the shutter speed
settings display in the sequence shown below.
When SUPER-D6 is turned off
When setting MANUAL of ALC/MANUAL
When SUPER-D6 is turned on
OFF
↔
AUTO
↔
1/120
↔
1/250
↔
1/500
↔
1/1000
1/10000
↔
1/4000
↔
1/2000
OFF
↔
AUTO
OFF
↔
X2 AUTO
↔
X4 AUTO
↔
X6 AUTO
X32 AUTO
↔
X16 AUTO
↔
X10 AUTO
OFF X2 AUTO X4 AUTO X6 AUTO X10 AUTO X16 AUTO
X64 FIX X32 FIX X16 FIX X10 FIX X6 FIX X4 FIX
X256 FIX
X128 FIX
OFF
X2 FIX
X32 AUTO
X512 FIX
Note:
• If operation of the system controller's IRIS (OPEN,
CLOSE) button during operation is done after the
menu is closed, the LEVEL on the CAMERA menu
is reflected and stored for these settings. However,
if the camera is in a preset position, it is reflected
as a parameter of the preset position. To return to
the initial factory default level, execute the system
controller’s iris reset.