13
Step 4
Press the [UP], [DOWN], [RIGHT], and [LEFT] buttons to move the flashing cursor to the area to be masked and press the [SET]
button.
When the selected area is masked, the masked area will start blinking (between stripes and white). When the flashing cursor is moved
to other areas, the masked area will be displayed in white.
Repeat the above procedure to mask other areas as necessary.
Note:
• To cancel the masking, select the masked area to be canceled, and then press the [SET] button. The masked area will be deleted.
Step 5
Hold down the [SET] button for more than 2 seconds after completion of masking.
→
Return to the previous menu.
Step 6
Move the cursor to “LEVEL” and press the [RIGHT] or [LEFT] button to adjust the level.
3. Electronic shutter setting [SHUTTER]
The variation in shutter speed allows users to perform the following.
• Increased shutter speed prevents blurring fast-moving subjects.
• If flicker is observed under fluorescent lighting of 60 Hz, selection of “1/120” for the speed can reduce flicker.
The shutter speed is selectable from the following.
OFF (1/50)
(default),
1/120
,
1/250
,
1/500
,
1/1000
,
1/2000
,
1/4000,
1/10000
,
1/120000
Note:
• When “ALC/ELC” is set to “ELC” or “ALC+”, “---” appears and the shutter function cannot be activated.
4. Gain control setting [AGC]
Select a gain control setting from the following.
ON (HIGH)
(default)/
ON (MID)
/
ON (LOW):
Automatically increases the gain to make the screen brighter when the illuminance of the
subject becomes darker.
HIGH, MID and LOW indicate the gain level.
OFF:
Does not increase the gain.
Note:
• When “SENS UP” is set to the AUTO mode, “AGC” cannot be set to “OFF”.
5. Electronic sensitivity enhancement setting [SENS UP]
Use of the electronic sensitivity enhancement function increases the light sensitivity of the CCD, and accordingly the image becomes
brighter. The magnification is unchanged for selection of FIX, and the magnification is automatically adjusted in accordance with the
illuminance of a photographic subject for selection of AUTO.
The magnification of the electronic sensitivity is selectable from the following.
Setting of the SUPER-D6 function restricts the available setting range.
When the SUPER-D6 function is set to "OFF":
OFF
(default)/
X2 AUTO
/
X4 AUTO
/
X6 AUTO
/
X10 AUTO
/
X16 AUTO
/
X32 AUTO
/
OFF
/
X2 FIX
/
X4 FIX
/
X6 FIX
/
X10 FIX
/
X16 FIX
/
X32 FIX
/
X64 FIX
/
X128 FIX
/
X256 FIX
/
X512 FIX
When the SUPER-D6 function is set to "ON":
OFF
(default)/
X2 AUTO
/
X4 AUTO
/
X6 AUTO
/
X10 AUTO
/
X16
/
AUTO
/
X32 AUTO