- 30 -
INSTALLATION
Precaution:
The following installations should be made by
qualified service personnel or system installers.
Setting the camera switches (only for WV-CSR600)
• To reset the communication parameters to the
factory preset values, for example, when
operating multiple cameras in a daisy chain
connection, set the switches inside the camera
as shown in the table below.
1. Disassemble the camera
Confirm the power is turned off.
Remove the screw from inside the hole for the
fall prevention wire. Hold the diecast case
containing the camera and rotate it to the left
as shown below.
Note:
Setting of switches while the power is on
may cause a malfunction. Make sure the
power is turned off before setting the
switches.
Switch A: Full duplex (four lines)/Half duplex
(two lines) switch
Switch B: Termination ON/OFF switch
Switch C: Dip switches (become effective when
the power is turned on)
Initialization of soft-
ware communication
parameters
DIP 3
OFF
ON
Normal Setting
Initial
Settings
Camera Unit No.
DIP 1 DIP 2
OFF
OFF
01 - 32
OFF
ON
33 - 64
ON
OFF
65 - 96
ON
ON
Inhibition
Notes:
• Select OFF after resetting the parameters by
selecting ON.
• The factory settings is OFF.
Diecast Case
2. Setting the switches
Set the switches as follows:
DIP
φ
ON
DIP Switches
OFF
DIP 1
DIP 2
DIP 3
Termination
ON
Half
(2 lines)
Switch A
Switch B
Full
(4 lines)
OFF
The factory settings for the dip switch 1 and 2 are
OFF both.