208
SEP 2004
Ver. 1.2
DP-1520P/1820P/1820E
005 Destination Code 000 : Austria
001 : U.K.
002 : Canada
003 : Denmark
004 : Taiwan
005 : Finland
006 : Germany
007 : Netherlands
008 : Italy
009 : Spanish
010 : Hong Kong
011 : Australia
012 : Switzerland
013 : Norway
015 : Portuguese
016 : Ireland
017 : Belgium
018 : Sweden
019 : Turkey
020 : U.S.A.
021 : France
022 : New Zealand
025 : Japan
029 : Poland
030 : Czech
031 : Russia
032 : Greece
033 : Hungary
034 : Indonesia
035 : South Korea
038 : Malaysia
039 : China
045 : Thailand
048 : South Africa
049 : Singapore
050 : Universal
051 : East Euro
Specified destinations only.
006 ID Display
1 = Number (Numeric ID)
2 = Chara (Character ID)
Selects the priority of displaying the ID.
007 JRNL Column
1 = Station
2 = RCV’D ID
Selects the contents of the ID to display on the
Journal.
008 Monitor
1 = Off
2 = On
Selects whether the Monitor is ON/OFF for
monitoring fax signals.
(FOR SERVICE USE ONLY)
009 DC Loop
1 = Off (Normal)
2 = On (Off Hook)
Selects a false Off Hook state for back to back
communication test.
010 TX Level
00 = 0 dBm
~
15 = -15 dBm
Selects the TX signal output level, 0 to -15 dBm in 1
dBm steps. (Refer to Chapter 4.3.)
011 RX Level
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
Selects the receiving sensitivity of -33/-38/-43/-48
dBm.
Function Parameter Table
No.
Parameter
Selections
Function
Summary of Contents for Workio DP-1520P
Page 98: ...98 SEP 2004 Ver 1 2 DP 1520P 1820P 1820E DETAIL A 28 35 31 32 33 34 30 29 ...
Page 464: ...464 SEP 2004 Ver 1 2 DP 1520P 1820P 1820E memo ...
Page 495: ...memo ...
Page 496: ...DZZSM00257 ...