122
8
Shutdown Time
Select a waiting time before starting the internal processing
against the power outage after an outage detection signal
has been supplied to the unit from the following.
10 s/20 s/30 s/1 m/2 m/3 m/4 m/5 m
8
Auto Copy
ON or OFF whether or not to copy recorded images to the
copy area on the hard disk automatically.
OFF:
Does not copy automatically.
ON:
Copies recorded images to the copy area on the hard
disk of this unit.
Important:
• When OFF is selected, the auto copy function at an
event occurrence and emergency recording will not
function.
• The auto copy will not work if a DVD-RAM disk drive is
not connected even though "COPY 1" or "COPY 2" is
selected.
• Images recorded (by pre-event recording) in the pre-
recording area in the extension unit will not be copied
automatically.
• When emergency recording/event recordings are per-
formed frequently, it may be possible that the auto copy
function does not function.
• Images to be copied automatically will be 30 minute’s
worth of images recorded from the start of emergency
recording/event recording.
●
[Time & Date] Setting of the date and time
Perform the following settings of the time and date.
8
Date Format
Select a display format for the date from the following. (Ex.
April 1, 2003)
YY.MM.DD:
03.4.1
MMM.DD.YY:
APR.1.03
DD.MMM.YY:
1.APR.03
8
Time Format
Select a display format for the time from the following. (Ex.
3 o’ clock in the afternoon)
12h:
3:00:00 PM
24h:
15:00:00
8
Time Setup
Adjust the current time and date.
Enter year, month, day, hour, minute and second in order,
move the cursor to "SET" and press the SET button.
Important:
Recording will stop for around 4 seconds just after set-
ting the date and time.
8
Auto Adjust Time
Select a method for auto time adjustment from the follow-
ing.
When "MASTER" is selected, a signal will be supplied from
the ALARM/CONTROL connector as the MASTER time (see
below) at the specified time.
OFF:
Does not function.
MASTER:
A signal will be supplied from the ALARM/CON-
TROL connector on the rear and the clock of the other
devices will be adjusted with reference to the time of
this unit.
SLAVE:
A signal will be supplied to the ALARM/CONTROL
connector on the rear and the clock of this unit will be
adjusted.
Important:
Recording will not be performed for around 4 seconds
when changing the present time (accurate to within ±5
seconds) using the time adjustment input (pin no.20) of
the ALARM/CONTROL connector on the rear panel.
8
Master Time
Specify the time when supplying a signal from the
ALARM/CONTROL connector.
8
Summer Time (Day Light Saving)
Select the method of switching to summer time from the fol-
lowing.
OFF:
Does not function.
ON:
Applies summer time.
AUTO:
Applies summer time in accordance with the setting
of summer time (see next page).
8
Summer Time (Day Light Saving) Table
Do the following to specify the start time and date and the
end time and date of summer time.
[Screenshot 1]
Start operation from the "Time & Date" menu.
Schedule
System
Comm
Switcher
SETUP MENU
LIVE
Maintenance
Recording
Event
Display
Basic Setup
Time & Date
User Regist.
User Edit
User Delete
Host Regist.
Host Edit
Host Delete
User Level
Save/Load
DD.MMM.YY
12H
SET
OFF
12
:00 AM
AUTO
SETUP
■
Date Format
■
Time Format
■
Time & Date
■
Auto Adjust Time
Master Time
■
Summer Time(Day Light Saving)
■
Summer Time(Day Light Saving)Table
AM
1
03
12
00
00
.
.
:
JAN
Schedule
System
Comm
Switcher
SETUP MENU
LIVE
Maintenance
Recording
Event
Display
Basic Setup
Time & Date
User Regist.
User Edit
User Delete
Host Regist.
Host Edit
Host Delete
User Level
Save/Load
DD.MMM.YY
12H
SET
OFF
12
:00 AM
AUTO
SETUP
■
Date Format
■
Time Format
■
Time & Date
■
Auto Adjust Time
Master Time
■
Summer Time(Day Light Saving)
■
Summer Time(Day Light Saving)Table
AM
1
03
12
00
00
.
.
:
JAN