<DURATION>
Move the cursor to the parameter box of each area
using the arrows button (
B
) and select a moving dura-
tion for an object in each area from the following using
the arrows button (
C D
).
--/5 s/10 s/20 s/30 s/40 s/50 s/1 m
c
To complete the settings, rotate the jog dial to select
"EXIT" on the status bar, and press the SET button.
→
The "VMD Setup" window will be closed.
8
About the Detection mode
Perform the settings of the detection mode (method of
detection) in the set detection area. Specifying a method of
detection in a detection area is available by setting the
detection mode.
There are three detection modes as follows.
Important:
Activating two or more detection modes simultaneously
is not possible.
<ANY AREA (to detect "motion" in the area)>
An event action will be performed according to the set-
tings when "motion" is detected in any of the set motion
detection areas.
Any motion will be detected anywhere in the A, B, C, D
areas.
<VECTOR (to detect object moving to a certain direc-
tion)>
An event action will be performed according to the set-
tings when an object moves within the set time to the
other detection area in the set order.
The following is an example.
Motion is detected in area B within 10 seconds after
being detected in area A.
Motion is detected in area C within 20 seconds after
being detected in area B.
Motion is detected in area D within 10 seconds after
being detected in area C.
When all of the above have occurred, an event action
will be performed.
<DURATION (to detect objects that keep moving in the
area)>
An event action will be performed according to the set-
tings when an object keeps moving for the set period in
the detection area. For example, in case of the following
settings; 10 sec. for the areas A and B, 20 sec. for area
C and 30 sec. for area D:
An event action will be performed when an object
keeps moving for 10 seconds in area A or B, or for 20
seconds in area C, or for 30 seconds in area D.
●
[Alarm Setup] Perform the settings for the
alarm auto reset and alarm disarm
Perform the settings for the alarm display duration. The
alarm display will automatically disappear when the display
duration has passed. (Alarm Auto Reset)
Perform the settings to suspend the set duration when the
same type of event (motion detection, video loss, terminal
alarm, command alarm) has occurred sequentially so that
the event action will not be performed each time. (Alarm
Disarm)
8
Alarm Auto Reset
The following are possible for the alarm auto reset.
When OFF is selected, the alarm display will not automati-
cally disappear.
To erase the alarm display, press the ALARM RESET but-
ton.
OFF/1 s - 30 s (in 1 second intervals)
40 s/50 s/1 m/2 m/3 m4 m/5 m
A
B
C
D
A
B
C
D
10 s
10 s
20 s
A
B
C
D
Event
Schedule
System
Display
Comm
Switcher
SETUP MENU
LIVE
Maintenance
Recording
Event Setup
VMD Setup
Alarm Setup
Terminal Setup
OFF
2s
■
Alarm Auto Reset
■
Alarm Disarm Time