-120-
TROUBLESHOOTING
A majority of the problems encountered in operating a matrix switcher can be traced to incorrect hardware or software setup.
Therefore, please read this section to see if your problem has a simple solution before requesting service.
1. Initialization Problems
Symptom: Matrix Switcher will not power up.
1. Check the power cord connection with the AC outlet.
2. Check the fuse, located in the fuse holder in the rear of the WJ-SX550A Matrix Switcher.
Symptom: System Controller(s) will not power up.
1. Check the power cord connection with the AC outlet.
2. Check that the ON/OFF switch, located in the rear of the WV-CU550A System Controller, is turned on.
Symptom: System Controller(s) will not log-in.
1. Ensure that the System Controller(s) is plugged into the correct ports on the Control Board of the WJ-SX550A Matrix
Switcher. The two ports labeled “Test” do not support System Controller inputs.
2. If not using the factory supplied data cable assembly, make sure that the distance from the Control Board to the System
Controller does not exceed the maximum recommended distance. Check that the proper grade of data cable is installed.
Also, check that the correct wiring sequences are maintained at all cable is installed. Also, check that the correct wiring
sequences are maintained at all cable splices, junctions and connectors.
2. Operational Problems
Symptom: Video from a specific camera cannot be displayed on a specific monitor.
1. If the camera cannot be displayed on any monitor, check the Operator Registration table and make sure that the
operator is authorized access to the camera in question.
2. If a monitor cannot be have any camera selected, check the Controller Table and make sure that controller can con-
trol the output of the monitor.
3. Check if the monitor has a Priority Lock set by another operator.
4. If the camera can be displayed on another monitor there may be a problem with the Video Output Board, call quali-
fied service personnel.
Symptom: No Pan/Tilt/Zoom control of a camera.
1. If the prompt field “PROHIBITED” appears on the LCD of the System Controller this indicates that the operator is not
authorized access to the Pan/Tilt/Zoom functions for that camera. If needed, change the Operator Registration table
programming for that operator.
Symptom: Can’t run a Program Sequence.
1. Check that the level of the operator allows access to running a Program Sequence.
2. Make sure that a Program Sequence has been programmed to run on that monitor.
Symptom: Camera does not reach the designated preset position and the preset number is not displayed on the moni-
tor, even though the preset position setting is specified in the Tour or Group Sequence prograrmming.
1. The programmed Dwell Time in the Tour or Group Sequence is not sufficiently long enough to allow the preset posi-
tion to be reached. Increase the Dwell Time.
Symptom: The Sequences (Program, Tour, Group) will not run at all or will not run properly, with respect to the Dwell
Time set, on a specific monitor.
1. Check in the External Timing Select Table if the monitor has EXT TIMING ON selected. If so, the dwell time of the
monitor is synchronized with time lapse mode set in the associated Time Lapse VTR.
Symptom: The Preset Test stops after one minute with the WV-CS500 Combination Camera
1. Make sure that the Control Site Mode Selection Switch (SW2) is set to the Multi-Site Mode On position.
7
Summary of Contents for WJ-CU550A
Page 3: ......
Page 7: ... 4 ...
Page 8: ... 5 BASIC OPERATION OF A MATRIX SWITCHER 1 ...
Page 14: ... 11 FEATURES OF THE SYSTEM 500 MATRIX SWITCHER 2 ...
Page 26: ... 23 DETAILED PRODUCT DESCRIPTION AND SELECTION 3 ...
Page 52: ... 48 ...
Page 53: ... 49 INSTALLATION AND SYSTEM CONNECTIONS 4 ...
Page 69: ... 65 SOFTWARE SETUP 5 ...
Page 96: ... 92 ...
Page 97: ... 93 OPERATING PROCEDURES 6 ...
Page 122: ... 118 ...
Page 123: ... 119 TROUBLESHOOTING 7 ...
Page 127: ... 123 SPECIFICATIONS 8 ...
Page 131: ... 127 9 INDEX ...
Page 135: ... 131 ...
Page 137: ......