3. Features
Inverter Technology
- Energy saving
High Efficiency
Compact Design
Environment Protection
- Non-ozone depletion substances refrigerant (R407C)
Long Installation Piping
- Long piping up to 30 meter with height difference 20 meter
- Flexible 4-way piping for outdoor unit
Easy to use control panel
- Holiday mode
- Dry concrete function
- Weekly timer setting
A-class energy efficiency pump
- Water pump speed can be set by selection at control panel
Weekly Timer setting
Protection Feature
- Random auto restart after power failure for safety restart operation
- Gas leakage protection
- Prevent compressor reverse cycle
- Inner protector to protect compressor
Serviceability Feature
- Breakdown Self Diagnosis function
- System Status Check Buttons for servicing purpose
- System Pumpdown Button for servicing purpose
- Front maintenance design for outdoor unit
Operation Condition
Indoor Outdoor
Water outlet temperature (°C)
Ambient temperature (°C)
Maximum 65
35
HEATING
Minimum 25
-20
NOTICE : When the outdoor temperature is out of the above temperature range, the heating capacity will drop significantly
and outdoor unit might stop for protection control.