174
UF-7300/7200
UF-8300/8200
Note 1:
Continuous Polling (Station Mode)
This feature allows you to Store or Add documents into a Polled file in memory.
To enable the Continuous Polling feature set the
Function Parameter No. 003
to
“2:STN”
(Station).
Depending on the setting of the
User Parameter (Facsimile)
“No. 119: QWERTY KEYBOARD”
,
one of the following operations is available:.
1. One-Touch
The upper "40" (40
↑
) Key is reserved for "Store 4 Polling" function, and cannot be changed.
To prepare document(s) to be polled, simply place the document(s) on the ADF, then press the
"-" (40) Key on the Keyboard (40
↑
= LOWER Indicator turned OFF) to Store or Add document(s)
into a Polled file.
2.Quick Name Search
Press "S" (13) Key to search the "Store 4 Polling" name instead.
To prepare document(s) to be polled, simply place the document(s) on the ADF and press the
"S" (13) Key to search for "Store 4 Polling", then press the "Start" Key to Store or Add
document(s) into a Polled file.
(
Note:
If a regular polled file is stored in memory, the Program Key for Continuous Polling will
not be accepted.)
Note 2:
Function Parameter No. 070 (Line Error)-Transmit condition of RTP/PIP or RTN/PIN
Note 3:
Function Parameter No. 071 (Total Error)-Transmit condition of RTP/PIP or RTN/PIN
Note 4:
The default setting of parameters depends on the country’s specifications or regulations. Print the
Function Parameter List to confirm the default settings.
Note 5:
200 Series Function Parameters Only appear when the G3 Communications Port Kit is installed
and follow the same numbering order.
122 LDAP
1 = Off
2 = On
Selects whether to use the LDAP Server. Special
characters used in the LDAP, may not be recognized
and display incorrectly.
123 ONE RING
SOUND
(USA and
Canada Only)
1 = Off
2 = On
When Function Parameter No. 45 "Ring Detect
Count" is set to 1 Ring, and this parameter is enabled
(On), the machine will only ring once out loud,
answering on the second ring count.
124 ~
199
Not Used
200 ~
299
-
See Note 5
Signal
Setting
1:128
2:256
3:512
4:1024
5:2048
6:Off
MCF/PIP
0-31
0-63
0-127
0-255
0-511
Always
RTP/PIP
32-63
64-127
128-255
256-511
512-1023
-
RTN/PIN
64-127
128-255
256-511
512-1023
1024-2047
-
Signal
Setting
1:5%
2:10%
3:15%
4:20%
MCF/PIP
0-2
0-4
0-7
0-9
RTP/PIP
3-4
5-9
8-14
10-19
RTN/PIN
5-
10-
15-
20-
Function Parameter Table