11
English
Precautions for use
Cautions when installing
Do not set up the Display outdoors.
•
The Display is designed for indoor use.
Install this unit at a location which can support the
weight of the unit.
•
Dropping or falling of the unit may cause injury.
Do not install the unit near a high-voltage line or a
power source.
•
Installing the unit near a high-voltage line or a power
source may receive interference.
Install the unit away from heat appliances.
•
Failure to do so may cause deformation of the cabinet
or malfunction.
Do not install the unit where it is 2 800 m (9 186 ft)
and higher above sea level.
•
Failure to do so may shorten the life of the internal
parts and result in malfunctions.
Environmental temperature to use this unit
•
When using the unit where it is below 1 400 m
(4 593 ft) above sea level: 0 °C to 40 °C (32 °F to
104 °F)
•
When using the unit at high altitudes (1 400 m
(4 593 ft) and higher and below 2 800 m (9 186 ft)
above sea level): 0 °C to 35 °C (32 °F to 95 °F)
We are not responsible for any product damage, etc.
caused by failures in the installation environment
even during the warranty period.
Transport only in upright position!
•
Transporting the unit with its liquid crystal panel
facing upright or downward may cause damage to the
internal circuitry.
Do not grab the liquid crystal panel.
•
Do not forcibly press the liquid crystal panel, or push
it with a pointed object. Applying a strong force to
the liquid crystal panel will cause unevenness of the
screen display, resulting in malfunction.
Do not install the product to a place where the
product is exposed to direct sunlight.
•
If the unit is exposed to direct sunlight even indoors,
the temperature rise of the liquid crystal panel may
cause malfunction.
In the case of storage, store the unit in a dry room.
Required space for ventilation
•
When installing the unit in a case or chassis, provide
a cooling fan or ventilation hole to ensure appropriate
ventilation so that the temperatures surrounding the
unit including the front surface of the liquid crystal
panel (temperature of inside the case or chassis)
can be maintained within the range of the operating
temperature of the unit.
About the screws used when using a wall hanging
bracket that conforms to VESA standards
Depth of screw hole
Screw for fixing the Display onto the wall-
hanging bracket (not supplied with the
Display)
●
Make sure that all screws are securely
tightened.
(View from the side)
Inch
model
Screw pitch for
installation
Depth of
screw hole
Screw
(quantity)
86
600 mm × 400 mm
20 mm
M8 (4)
75
600 mm × 400 mm
20 mm
M8 (4)
65
400 mm × 400 mm
20 mm
M8 (4)
55
400 mm × 400 mm
18 mm
M6 (4)
50
400 mm × 400 mm
20 mm
M6 (4)
43
200 mm × 200 mm
16 mm
M6 (4)
Note for connection
Removing and inserting the power cord and
connection cables
•
When the unit has been installed on the wall, if the
power cord and connection cables are difficult to
remove and insert, make connections first before
installation. Be careful not to allow the cables to be
entangled. After installation is completed, insert the
power plug to the outlet.
When using
Image retention may occur.
•
If you display a still picture for an extended period, the
image might remain on the screen. However, it will
disappear when a general moving picture is displayed
for a while.
When polarization sunglasses are worn, the screen
display may be invisible.
•
This phenomenon occurs due to deflection
characteristics of the liquid crystal panel. This is not a
malfunction.
Red, blue or green dots on the screen are a liquid
crystal panel-specific phenomenon. This is not a
malfunction.
•
Although the liquid crystal display is manufactured
with high-precision technology, always-lighting dots or
non-lighting dots may appear on the screen. This is
not a malfunction.
Inch model
Dot omission ratio
*
86
0.00009% or less
75
0.00007% or less
65
0.00005% or less
55
0.00005% or less
50
0.00005% or less
43
0.00005% or less
*:
Calculated in sub-pixel units according to the
ISO09241-307 standard.