© Panasonic Industrial Devices SUNX Co., Ltd. 2014
24
Mounting
<In case of using intermediate supporting bracket for use with standard mounting brack
-
et MS-SF4BC-5 (optional)>
Step 1 Secure the bracket with two M3 flat head screws (purchase separately). The tightening
torque should be 0.5N•m.
<In case of rear mounting>
M3 flat head screws
(Purchase separately)
Intermediate supporting bracket for
use with standard mounting bracket
MS-SF4BC-5
(Optional)
9.8mm
20mm
<In case of side mounting>
M3 flat head screws
(purchase separately)
Intermediate supporting bracket for
use with standard mounting bracket
MS-SF4BC-5
(Optional)
20mm
15mm
13.7mm
Step 2 Insert this device into the intermediate supporting bracket.
<In case of rear mounting>
Main body
<In case of side mounting>
Main body
Note:
SF4B-H□C□
: 48 beam channels or more,
SF4B-A□C□
: 24 beam channels or more require intermediate
supporting bracket for use with standard mounting bracket
MS-SF4BC-5
(optional).
SF4B-H40C
□,
SF4B-H48C
□,
SF4B-H56C
□,
SF4B-A20C
□,
SF4B-A24C
□,
SF4B-A28C
□: 1 set
SF4B-H64C
□,
SF4B-H72C
□,
SF4B-H80C
□,
SF4B-H88C
□,
SF4B-H96C
□,
SF4B-A32C
□,
SF4B-A36C
□,
SF4B-A40C
□,
SF4B-A44C
□,
SF4B-A48C
□: 2 sets
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com