© Panasonic Industrial Devices SUNX Co., Ltd. 2014
42
Wiring
*S1
Switch S1
●
Emission halt input / Reset input
For manual reset ... 0 to +1.5V (source current 5mA or less): Emission halt, Open: Emission
For auto-reset ... 0 to +1.5V (source current 5mA or less): Emission, Open: Emission halt
●
Interlock setting input, Override input, Muting input A / B, External device monitor input
0 to + 1.5V (source current: 5mA or less): Valid, Open: Invalid
●
Large multi-purpose indicator input
0 to + 1.5V (source current: 5mA or less): Lights up, Open: Turn OFF
<Reference>
●
K1, K2: External device (Forced guided relay or magnetic contactor)
● For more information about wiring, refer to Section 2-5-4 and subsequent sections.
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com