CC-LINK Network Communication
WUME-SCHG1C-4
4-45
Command
Attribute
Name
Response/Setting parameter
HG-T
Series
0x0364
W
Beam axis adjustment end
End beam axis adjustment.
Specify "0".
0x0365 to 0x036F
-
System reserved
Do not use.
0x0370
R
Waveform read setting
(Note 3)
bit0 to bit7 : Select a waveform type.
0x00 : Reference waveform
0x10 : Waveform during beam axis adjust-
ment
0x11 : Measured waveform
bit8
: Reserved
bit9
: Status
0: Waveform information has not
been saved
(For example, immediately after
the unit starts up, operation
mode is changed, or measured
values are reset)
1: Waveform information has been
saved
bit10 to bit15: Reserved
W
bit0 to bit7 : Select a waveform type.
0x00 : Reference waveform
0x10 : Received light waveform during
beam axis adjustment
0x11 : Measured waveform
b i t 8 t o
bit15
: Reserved
Always set "0x01".
0x0371
R
Waveform read data 1
Obtains four bytes of received light waveform
data (“Received light intensity 0” to “Received
light intensity 3”)
0x0372
R
Waveform read data 2
Obtains four bytes of received light waveform
data (“Received light intensity 4” to “Received
light intensity 7”)
0x0373
R
Waveform read data 3
Obtains four bytes of received light waveform
data (“Received light intensity 8” to “Received
light intensity 11”)
0x0374
R
Waveform read data 4
Obtains four bytes of received light waveform
data (“Received light intensity 12” to “Received
light intensity 15”)
0x0375
R
Waveform read data 5
Obtains four bytes of received light waveform
data (“Received light intensity 16” to “Received
light intensity 19”)
0x0376
R
Waveform read data 6
Obtains four bytes of received light waveform
data (“Received light intensity 20” to “Received
light intensity 23”)
0x0377
R
Waveform read data 7
Obtains four bytes of received light waveform
data (“Received light intensity 24” to “Received
light intensity 27”)
0x0378
R
Waveform read data 8
Obtains four bytes of received light waveform
data (“Received light intensity 28” to “Received
light intensity 31”)
0x0379
R
Waveform read data 9
Obtains four bytes of received light waveform
data (“Received light intensity 32” to “Received
light intensity 35”)
0x037A
R
Waveform read data 10
Obtains four bytes of received light waveform
data (“Received light intensity 36” to “Received
light intensity 39”)
Summary of Contents for SC-HG1-C
Page 2: ...WUME SCHG1C 4 2 MEMO ...
Page 8: ...WUME SCHG1C 4 8 MEMO ...
Page 16: ...WUME SCHG1C 4 1 8 MEMO ...
Page 17: ...2 1 2 System Configuration 2 1 Communication unit system 2 2 2 2 Unit types 2 4 ...
Page 22: ...WUME SCHG1C 4 2 6 MEMO ...
Page 106: ...WUME SCHG1C 4 4 72 MEMO ...
Page 107: ...5 1 5 Specifications 5 1 Specifications 5 2 5 2 Dimensions 5 3 ...
Page 110: ...WUME SCHG1C 4 5 4 MEMO ...
Page 111: ...6 1 6 Warranty 6 1 When you purchase and use the product 6 2 ...
Page 114: ...WUME SCHG1C 4 6 4 MEMO ...
Page 124: ...WUME SCHG1C 4 8 8 MEMO ...
Page 126: ... MEMO ...
Page 127: ... MEMO ...