CC-LINK Network Communication
WUME-SCHG1C-4
4-36
Command
Attribute
Name
Response/Setting parameter
HG-S
series
0x0054
W
2nd point calibration execution
(CL.SET2)
Acquire the 2nd point measurement value.
Specify "0".
0x0055
R/W 1-point teaching tolerance set-
ting (TOL<±>)
Integer indicating minimum resolution units of
controller.
-1999999 to 1999999
0x0056
W
1st point teaching execution
(SET.1)
Execute 1st point of teaching.
Specify "0".
0x0057
W
2nd point teaching execution
(SET.2)
Execute 2nd point of teaching.
Specify "0".
0x0058
W
3rd point teaching execution
(SET.3)
Execute 3rd point of teaching.
Specify "0".
0x0059 to 0x005D
-
SOther model command area Do not use.
0x005E to 0x009F
-
System reserved
Do not use.
0x00A0
R
Fault
bit0 : Controller memory function damaged
bit1 : Sensor head memory function damaged
bit2 : Output section short-circuit error
bit3 : Detection circuit damaged
bit4 : System error
0x00A1
-
System reserved
Do not use.
0x00A2
R
Notification
bit0 : Sensor head unconnected
bit2 : Connected unit count check error
bit3 : NPN / PNP output type mixture error
bit4 : Calculated unlit count error
bit5 : Copy executionerror ( Slave unit problem)
bit10 : Out-of-specification pressure error
bit11 : Catch check
bit12 : Pressure check
0x00A3 to 0x00FF
-
System reserved
Do not use.
0x0100
R/W Leverage ratio (LEVER)
Leverage ratio ×10 1 to 1000
0x0101
R/W Pressure check (PRS.CHK)
0: OFF
1: ON
0x0102
R/W Set value for pressure check
(PRS.SET)
Integer indicating minimum resolution units of
controller.
-1999999 to 1999999
0x0103
R/W Stuckness check (CAT.CHK)
0: OFF
1: ON
0x0104
R/W Hold setting (HOLD)
Set the sum of the values below according to the
states of the measurement mode, trigger mode,
self trigger edge direction, and self trigger delay
settings.
• Measurement mode (MEAS)
0x0000 = Sample hold
0x1000 = Peak hold
0x2000 = Bottom hold
0x3000 = Peak to peak hold
0x4000 = Peak to peak hold P-P/2
0x5000 = NG hold
0x6000 = Self sample hold
0x7000 = Self peak hold
0x8000 = Self bottom hold
• Trigger mode (TRIG)
0x000 = One-shot
0x100 = Hold
• Self trigger edge direction (SLF.EDG)
0x00 = Rising
0x10 = Falling
• Self trigger delay (SLF.DLY)
0x0 = Static width
0x1 = Delay timer
Summary of Contents for SC-HG1-C
Page 2: ...WUME SCHG1C 4 2 MEMO ...
Page 8: ...WUME SCHG1C 4 8 MEMO ...
Page 16: ...WUME SCHG1C 4 1 8 MEMO ...
Page 17: ...2 1 2 System Configuration 2 1 Communication unit system 2 2 2 2 Unit types 2 4 ...
Page 22: ...WUME SCHG1C 4 2 6 MEMO ...
Page 106: ...WUME SCHG1C 4 4 72 MEMO ...
Page 107: ...5 1 5 Specifications 5 1 Specifications 5 2 5 2 Dimensions 5 3 ...
Page 110: ...WUME SCHG1C 4 5 4 MEMO ...
Page 111: ...6 1 6 Warranty 6 1 When you purchase and use the product 6 2 ...
Page 114: ...WUME SCHG1C 4 6 4 MEMO ...
Page 124: ...WUME SCHG1C 4 8 8 MEMO ...
Page 126: ... MEMO ...
Page 127: ... MEMO ...