CC-LINK Network Communication
WUME-SCHG1C-4
4-35
Command
Attribute
Name
Response/Setting parameter
HG-S
series
0x0023
R
Minimum value during P-P
measurement
Integer indicating minimum resolution units of
controller.
If the measurement mode is not P-P or P-P/2, a
judgment value is output.
-1999999 to 1999999
0x0024 to 0x003F
-
System reserved
Do not use.
0x0040
R/W Preset (PRESET)
0: OFF
1: ON
0x0041
R/W Preset value (PR. VAL)
Integer indicating minimum resolution units of
controller.
-1999999 to 1999999
0x0042
R/W Preset data selection
(PR.OBJ)
0: Normal measured value (NORM.V)
1: Judgment value (JUDGE.V)
0x0043
R/W Preset save (PR.SAVE)
0: OFF
1: ON
0x0044
R/W Label 1 (LABEL)
Label [1st to 4th character]
Part of character code is usable. (Note 1)
0x0045
R/W Label 2 (LABEL)
Label [5th to 6th character]
Part of character code is usable. (Note 1)
0x0046
R/W Response time (SPEED)
0: 3ms
1: 5ms
2: 10ms
3: 100ms
4: 500ms
5: 1000ms
0x0047
R/W Measurement direction
(DIRECT)
0: Normal display
1: Reverse display
0x0048
R/W Alarm delay count (DELAY)
Delay count: 1 to 1000
0x0049
R/W Teaching type (TEACH)
0: 1-point teaching
1: 2-point teaching
2: 3-point teaching
0x004A
R/W Input all (ALL IN)
0: Individual input
1: Simultaneous input
0x004B
R/W External input (EXT.IN)
0: Preset / Reset / Trigger (P/R/T)
1: Bank A / Bank B / Preset (BANK/P)
2: Bank A / Bank B / Reset (BANK/R)
3: Bank A / Bank B / Trigger (BANK/T)
0x004C
R/W External output (EXT.OUT)
0: 3-value (3VAL)
1: 2-value (2VAL)
2: Logic (LOGIC)
3: Logic 2 (LOGIC2)
0x004D
R/W Analog scaling (ANALOG)
0: Default
1: Free
0x004E
R/W Scaling upper limit value
(ANA.HI)
Integer indicating minimum resolution units of
controller.
-1999999 to 1999999
0x004F
R/W Scaling lower limit value
(ANA.LO)
Integer indicating minimum resolution units of
controller.
-1999999 to 1999999
0x0050
R/W Number of digits displayed
(DIGIT)
0: 0.0001
1: 0.001
2: 0.01
3: 0.1
0x0051
R/W Calibration selection
(CAL.SEL)
0: Default
1: User setting
0x0052
W
1st point calibration execution
(CL.SET1)
Acquire the first point measurement value.
Specify "0".
0x0053
R/W
2nd point calibration target
value
(AJ.VAL2)
Integer indicating minimum resolution units of
controller.
-1999999 to 1999999
Summary of Contents for SC-HG1-C
Page 2: ...WUME SCHG1C 4 2 MEMO ...
Page 8: ...WUME SCHG1C 4 8 MEMO ...
Page 16: ...WUME SCHG1C 4 1 8 MEMO ...
Page 17: ...2 1 2 System Configuration 2 1 Communication unit system 2 2 2 2 Unit types 2 4 ...
Page 22: ...WUME SCHG1C 4 2 6 MEMO ...
Page 106: ...WUME SCHG1C 4 4 72 MEMO ...
Page 107: ...5 1 5 Specifications 5 1 Specifications 5 2 5 2 Dimensions 5 3 ...
Page 110: ...WUME SCHG1C 4 5 4 MEMO ...
Page 111: ...6 1 6 Warranty 6 1 When you purchase and use the product 6 2 ...
Page 114: ...WUME SCHG1C 4 6 4 MEMO ...
Page 124: ...WUME SCHG1C 4 8 8 MEMO ...
Page 126: ... MEMO ...
Page 127: ... MEMO ...