![Panasonic S-71WF3E Service Manual Download Page 85](http://html.mh-extra.com/html/panasonic/s-71wf3e/s-71wf3e_service-manual_1507724085.webp)
85
11.3.3.2 Installer
Setup
1
System setup
Optional PCB connectivity
Yes/No
2
Only when the selection for Optional PCB is Yes
Zone & Sensor
1 Zone system / 2 Zone system
Zone settings
3
Heater capacity
Capacity select
4
Anti freezing
5
DHW Capacity
Variable/Standard
6
Only when the selection for Optional PCB is Yes
Buffer Tank connection
Yes/No
∆T setup
7
Tank Heater
Internal
On timer setup
8
Bivalent connection
Yes/No
Bivalent setup
9
External SW
Yes/No
10
Only when the selection for Optional PCB is Yes
Solar connection
Yes/No
Tank setup
Solar setup
11
Only when the selection for Optional PCB is Yes
External Error signal
Yes/No
12
Only when the selection for Optional PCB is Yes
SG ready
Yes/No
Capacity setup
13
Only when the selection for Optional PCB is Yes
External Compressor SW
Yes/No
14
Circulation liquid
Water/glycol
15
Force Heater
Auto/Manual
16
Defrost Signal
Yes/No
17
Pump flowrate
∆T/ Max. Duty
18
Force DHW
Auto/Manual
19
DHW Defrost
Yes/No
Yes/No