Chapter 7
Appendix — Attaching the Smoke Cut Filter Unit (optional)
262 - ENGLISH
10) When the confirmation screen is displayed, press
qw
to select [OK], and press the <ENTER> button.
f
The [PROJECTOR SETUP] menu
→
[STATUS]
→
[FILTER COUNTER] is displayed as “0”.
Attention
f
When use of the Smoke Cut Filter is finished and replaced with a standard air filter unit, make sure to reset the filter counter after setting
[PROJECTOR SETUP] menu
→
[FILTER SETTING]
→
[FILTER TYPE] to [NORMAL]. When the [PROJECTOR SETUP] menu
→
[FILTER
SETTING]
→
[FILTER COUNTER RESET] is executed, the filter counter is reset.
Note
f
[FILTER TYPE] cannot be set to [SMOKE CUT] when the [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING
MODE] is set to [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3]. Set [OPERATING MODE] to anything other than [LONG LIFE1], [LONG
LIFE2], or [LONG LIFE3] when using the Smoke Cut Filter.
f
Continuing to use the projector with incorrect [FILTER TYPE] setting may cause failure of the projector.
f
When the projector is used without resetting the filter counter, the actual filter runtime (counter numeric value) will not be able to be
confirmed.
f
When replacing the Smoke Cut Filter, remove the used Smoke Cut Filter by performing Steps
1)
and
2)
in “Attaching the Smoke Cut Filter”
(
x
page 261) in the reverse order.
f
When use of the Smoke Cut Filter is finished and replaced with the air filter unit, perform the steps in “Attaching the Smoke Cut Filter”
(
x
page 261) and “Removing the air filter unit” (
x
page 260) in the reverse order to replace.