Chapter 4
Settings — [PROJECTOR SETUP] menu
ENGLISH - 169
2) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Disables the AC voltage monitor function.
[ON]
Enables the AC voltage monitor function.
Note
f
When [ON] is set, the value of the input supply voltage is always displayed in the self-diagnosis display while the main power of the projector
is turned on.
f
Even when [OFF] is set, the value of input supply voltage can be displayed temporarily in the self-diagnosis display by operating the button
on the remote control. (
x
page 82)
f
The value of input supply voltage cannot be displayed in the self-diagnosis display during standby when the [PROJECTOR SETUP] menu
→
[STANDBY MODE] (
x
page 158) is set to [ECO].
[FILTER SETTING]
Set the type of filter. The filter runtime (counter numeric value) can also be reset.
Setting [FILTER TYPE]
Set the type of filter attached to the projector.
1) Press
as
to select [FILTER SETTING].
2) Press the <ENTER> button.
f
The
[FILTER SETTING]
screen is displayed.
3) Press
as
to select [FILTER TYPE].
f
The
[FILTER TYPE]
screen is displayed.
4) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[NORMAL]
Factory default setting. Select this item when the Replacement Filter Unit (Model No.: ET-EMF330)
(accessory/optional accessory) is attached to the projector.
When the [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING MODE] is set
to [HIGH], the recommend time to replace the filter is set to 2 000 hours.
When the [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING MODE] is
set to [NORMAL], [USER1], [USER2], or [USER3], the recommend time to replace the filter is set to
4 000 hours.
When the [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING MODE] is set
to [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3], the recommended time to replace the filter is not
set.
[LONG LIFE]
Select this item when the optional Long Life Filter Unit (Model No.: ET-EMFU330) is attached to the
projector.
When the [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING MODE] is set
to [HIGH], the recommend time to replace the filter is set to 4 000 hours.
When the [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING MODE] is set
to anything other than [HIGH], the recommended time to replace the filter is not set.
[SMOKE CUT]
Select this item when the optional Smoke Cut Filter (Model No.: ET-SFR330) is attached to the
projector.
When the [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING MODE] is set
to [HIGH], the recommend time to replace the filter is set to 50 hours.
When the [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING MODE] is set
to [NORMAL], [USER1], [USER2], or [USER3], the recommend time to replace the filter is set to 100
hours.
Note
f
The [PROJECTOR SETUP] menu
→
[OPERATION SETTING]
→
[OPERATING MODE] cannot be set to [LONG LIFE1], [LONG LIFE2],
or [LONG LIFE3] when [FILTER TYPE] is set to [SMOKE CUT]. Set [OPERATING MODE] to [HIGH], [NORMAL], [USER1], [USER2], or
[USER3] when using the optional Smoke Cut Filter (Model No.: ET-SFR330).
f
If the runtime of the filter exceeds the recommended time to replace the filter that is set, the time is displayed in red in the following menu.
Perform maintenance or replacement of the filter.
g
[FILTER SETTING]
→
[FILTER COUNTER RESET]
g
[STATUS]
→
[FILTER COUNTER]
f
Perform maintenance or replacement of the filter in the following cases.
g
The filter is clogged, causing the filter replacement message to appear on the screen and the filter indicator <FILTER> to light in red.
f
Continuing to use the projector with incorrect settings may cause failure.