Chapter 7
Appendix — Technical information
196 - ENGLISH
r
GEOMETRY
Performance
Parameter
Default value
OFF
0-15
255
KEYSTONE
16-31
CURVED CORRECTION
32-47
PC-1
48-63
PC-2
64-79
PC-3
80-95
CORNER CORRECTION
96-111
No operation
112-255
r
CUSTOM MASKING
To use PC-1, PC-2, or PC-3, the optional Upgrade Kit (Model No.: ET-UK20) is required.
Performance
Parameter
Default value
OFF
0-31
255
PC-1
32-63
PC-2
64-95
PC-3
96-127
No operation
128-255
r
FREEZE
Performance
Parameter
Default value
No operation
0-31
128
OFF
32-95
No operation
96-159
ON
160-223
No operation
224-255
r
COLOR, TINT
Performance
Parameter
Default value
No operation
0-31
0
Factory default setting
32-63
-31
64-65
…
…
0
128-129
…
…
+31
190-191
No operation
192-255
r
RASTER PATTERN
Performance
Parameter
Default value
No operation
0-15
0
OFF
16-31
WHITE
32-47
YELLOW
48-63
CYAN
64-79
GREEN
80-95
MAGENTA
96-111
RED
112-127
BLUE
128-143
BLACK
144-159
USER LOGO
160-175
No operation
176-255