[WARNING] items
Item
Description
[AC POWER]
AC input voltage is weak. Use electric wiring that can sufficiently withstand the power
consumption of the projector.
[LOW-TEMPERATURE]
The temperature around the optics module inside the projector is low. Projection cannot
be started until the optics module becomes warm.
[INTAKE AIR TEMPERATURE]
The intake air temperature is high. The projector may be used in an environment where
the temperature is high, such as near a heating appliance.
[OPTICS MODULE TEMPERATURE]
The temperature around the optics module inside the projector is high. The projector
may be used in an environment where the temperature is high, such as near a heating
appliance.
[EXHAUST AIR TEMPERATURE]
The exhaust air temperature is high. The air exhaust port may be blocked.
[LD1 TEMPERATURE]
The temperature of the light source is high. The projector may be used in an
environment where the temperature is high, such as near a heating appliance.
[LD2 TEMPERATURE]
[Network status] page
Click [Status]
→
[Network status].
The current network setting status is displayed.
[Access error log] page
Click [Status]
→
[Access error log].
The error log on the web server is displayed such as access to the pages that do not exist or access with unauthorized user names or
passwords.