![Panasonic NA-D106X1 Service Manual Download Page 53](http://html.mh-extra.com/html/panasonic/na-d106x1/na-d106x1_service-manual_282006053.webp)
53
NA-D106X1
*Unable to detect the water level 150mm or
less in 5 minutes (after the initial drainage
has started during the washing process).
(Water is supplied)
• Check the water leakage caused by
clogging of valve.
• Check the leakage from other section.
Press Start/Pause
button in door closed
condition.
Cleared error code
display and back to
initial position of
washing process.
U18
Drainage filter has
come off
The drainage filter has come off during
operation. (Detected by the SF switch (hall
sensor U) for drainage filter.)
• Check the drainage filter has not come
off. If the drainage filter has not come
off.
• Check the connector of SF switch (hall
sensor U) has not come off.
• Check the electric continuity of SF
switch.
Attach the drainage
filter properly in door
closed condition.
Cleared error code
display and resume
the operation.
H01
Malfunction of water
level (water-pressure)
sensor
The input frequency from a water level
sensor to a microcomputer is out of the
specified range.
• Check the connector has not come off.
• Check the contact failure of connector.
• Check the breakage of lead wire.
• Replace the water level sensor.
• Except as described above, replace the
controller unit(Power side).
• Power button off
and on again.
H04
Detection of short
circuit of power relay 1.
Short circuit of power relay 1 in a
controller(Power side) is detected.
• Replace the controller unit(Power side). Pull out the power
plug.
H05
Malfunction of the
memory
Service check B, unable to write data to
memory.
• Replace the controller unit(Power side). Power button off and
on again.
H07
Malfunction of rotation
sensor
There is no input signal from the rotation
sensor during the motor ON process.
• Check the contact failure of motor's
connector and breakage of lead wire.
• Replace the motor.
• Except as described above, replace the
controller unit(Power side ).
Power button off and
on again.
H09
Breakage of
communication line
Unable to communicate between the
controller(Power side) and controller
(Display side) during the power ON
condition.
• Check the breakage of communication
line.
• Check the contact failure of connector.
• Check the failure of the controller
(Display side) or the controller
unit(Power side ).
Pull out the power
plug and plug in
again.
H10
Malfunction of Warm
air thermistor.
Open circuit or short circuit is caused in the
Warm air thermistor (TH3).
• Open condition : more than 206k
• Short condition : less than 96
• Check the connector has not come off.
• Replace the thermistor (TH3).
Power button off and
on again.
H11
Malfunction of Exhaust
air thermistor.
Open circuit or short circuit is caused in the
Exhaust air thermistor (TH1).
• Open condition : more than 206k
• Short condition : less than 96
• Check the connector has not come off.
• Replace the thermistor (TH1).
Power button off and
on again.
H14
Abnormal differential
temperature of Inlet air
and Exhaust air
temperature thermistor
Mean differential temperature between
Exhaust air thermistor (TH1) and Inlet air
sensor (TH2) exceed more than 30 bit.
Thermistor calibration has not completed.
• Cooling down body sufficiently, and
have the calibration again.
Power button off and
on again.
H15
Malfunction of Inlet air
thermistor.
Open circuit or short circuit is caused in the
Inlet air thermistor (TH2).
• Open condition : more than 206k
Ω
• Short condition : less than 96
Ω
• Check the connector has not come off.
• Replace the thermistor (TH2).
• Power button off
and on again.
H17
Malfunction of Warm
water thermistor.
Open circuit or short circuit is caused in the
Warm water thermistor.
• Open condition : more than 206k
Ω
• Short condition : less than 94
Ω
• Check the contact failure of connector.
• Check the resistance of thermistor as
single item. If the open circuit or short
circuit is caused, replace the sensor.
• If there is no error on the sensor, check
the breakage of lead wire.
Power button off and
on again.
H20
Warm water thermistor
has come off.
Unable to detect the temperature rise in 10
minutes from 1 minute after water supply
agitation process has started during the
washing process.
• Error data is memorized only.
• Error is not displayed.
• Check the position displacement of
warm water sensor.
• Check the blowout of the thermal fuse
and current fuse.
• Check the connector has not come off.
• Check the water heater and breakage of
lead wire.
Continued the
operation and
unnecessary to clear
the error.
H21
Overflow detection
Water level sensor detects an overflow
water level for longer than the specified
time during the washing rinse process and
preset timer standby.
*The Drain pump for drainage is operated
and water is drained.
• Replace the water supply valve.
• Replace the controller unit(Power side).
(If the feeding valve cannot be stopped
by the controller unit output
continuously on.)
Power button off and
on again.
*The warning buzzer
beeps.
Display
Contents
Detection contents
Check point
Method to clear error
Summary of Contents for NA-D106X1
Page 2: ...2 NA D106X1 1 Safety Precautions ...
Page 4: ...4 NA D106X1 3 General Introduction 3 1 Location of Components and Accessories ...
Page 5: ...5 NA D106X1 4 Control panel ...
Page 7: ...7 NA D106X1 5 3 Active Foam system 5 4 ECONAVI ...
Page 8: ...8 NA D106X1 5 5 Eco Drying system ...
Page 9: ...9 NA D106X1 6 Installation Instructions ...
Page 10: ...10 NA D106X1 ...
Page 11: ...11 NA D106X1 ...
Page 12: ...12 NA D106X1 ...
Page 13: ...13 NA D106X1 7 Operating Instructions 7 1 Door Lock and Child Lock ...
Page 14: ...14 NA D106X1 7 2 Laundry Procedure ...
Page 15: ...15 NA D106X1 7 3 Selecting the Program ...
Page 16: ...16 NA D106X1 7 4 How to Put in Detergent and Sofetner ...
Page 17: ...17 NA D106X1 7 5 Everyday Washing ...
Page 18: ...18 NA D106X1 7 6 Washing Options ...
Page 19: ...19 NA D106X1 ...
Page 20: ...20 NA D106X1 7 7 Drying ...
Page 21: ...21 NA D106X1 7 8 Maintenance ...
Page 22: ...22 NA D106X1 ...
Page 23: ...23 NA D106X1 7 9 Changing the Settings ...
Page 24: ...24 NA D106X1 7 10 Program Details ...
Page 46: ...46 NA D106X1 9 Wiring Diagram OUTLINE Drawing 9 1 NA D106X1 Wiring Diagram ...
Page 47: ...47 NA D106X1 9 2 Measure Input and Output value of Controller Power side ...
Page 56: ...56 NA D106X1 11 External Diameter ...
Page 57: ...57 NA D106X1 ...
Page 58: ...58 NA D106X1 12 Exploded View and Replacement Parts List 12 1 Parts Exploded View Part A ...
Page 60: ...60 NA D106X1 12 3 Parts Exploded View Part B ...
Page 62: ...62 NA D106X1 12 5 Parts Exploded View Part C ...
Page 64: ...64 NA D106X1 12 7 Parts Exploded View Part D ...
Page 66: ...66 NA D106X1 12 9 Parts Exploded View Part E ...