background image

English

B11

B12

Maintenance and Inspections

Repair

Maintenance/ Inspections

Routine maintenance and inspection are essential for proper and satisfactory operation of 

the motor.

Maintenance/ Inspection item

Maintenance/

Check item

Inspection

procedure

Condition

Input voltage

Voltmeter  Must be within ±10% of rating.

Input current

Ammeter  Must be within rated input current described on nameplate.

Insulation

resistance

Insulation 

resistance 

tester 

The resistance of motor should be 1 MΩ or higher when tested 

with a 500 V megger.

Measuring position: 

   Between power input line (L1, L2,L3) and grounding wire

Brushless motor: 

   Across phase (U, V, W) and ground terminals

Noise 

Hearing

Noise level must not be different from the usual level. In addition, 

abnormal noise such as rumbling noise must not be heard. 

Vibration

By hand

Free from abnormal vibration. 

Grease 

leakage

Visual check

Check that circumference of the motor and gear head are free 

from oil and grease.

If grease leakage will cause problem, use grease sealing cover.

Installation 

bolt 

Torque 

wrench 

Check for loosening of bolt, and tighten additionally as 

necessary. 

Use 

environment

By sight

Check the ambient temperature and humidity, and make sure 

that dirt, dust, or foreign substance is not found. 

Caution

• Power-on/off operations should be done by the operators themselves for ensuring safety 

in checking.

• Do not touch the motor while it is running or immediately after it stops because it gets hot 

and stays hot for a while after power has been turned off.

• When testing the insulation resistance of the brushless amplifier with the megger, discon-

nect the amplifier from all associated devices. Performing megger testing without first 

disconnecting these devices will cause failure.

When disassembly, troubleshooting, etc., is needed,

be sure to contact our service department or the sales agent of purchase.

Repair

• Consult to a dealer from whom you have purchased the product for details of repair.

  When the product is incorporated to the machine or equipment you have purchased, 

consult to the manufacturer or the dealer of the machine or equipment.

Technical information

• Technical information of this product (Operating Instructions, CAD data) can be 

downloaded from the following web site.

    industrial.panasonic.com/ac/e/

Summary of Contents for MINAS-BL GU series

Page 1: ...ifier MINAS BL GU series Before operating this product please be sure to read the Operating Instructions You can download the Operating Instructions from Panasonic Web Site industrial panasonic com ac...

Page 2: ...J1 J2 U V W CS...

Page 3: ...J3 J4 J3 15...

Page 4: ...P54 P 1 8 0 4 0 0 0 1 2 2 0 1 8 0 4 0 1 Model No Voltage INPUT OUTPUT Phase F L C Freq Power 200 240 V 1 3 0 7 A 0 35 A 50 60 Hz 0 240 V 3 0 6 A 0 267 Hz 50 W Ser No P18040001G BRUSHLESS AMPLIFIER MBE...

Page 5: ...200 V DV0P4170 SUP EK5 ER 6 DV0PM20042 3SUP HU10 ER 6 MCCB W MCCB mm2 100 V 50 130 5 A 20 A 3P 1a 0 5 AWG20 0 13 AWG26 200 V 50 130 5 A 20 A 3P 1a 0 5 AWG20 0 13 AWG26 200 V 50 130 5 A 20 A 3P 1a 0 5...

Page 6: ...o 274 2 1 EC 61800 5 1 EMC 55011 61000 6 2 61000 6 4 61800 3 EMC 2 Group 1 Class A EMI Category C3 2nd environment KC 2 Class A 1 SCCR 5000 Arms 240 V NEC 2 A A BRUSHLESS AMPLIFIER Class A BRUSHLESS A...

Page 7: ...J11 J12 1 1 6 0120 70 3799 TEL 072 870 3057 FAX 072 870 3120 9 00 12 00 13 00 17 00 TEL 072 870 3123 FAX 072 870 3152 9 00 12 00 13 00 17 00 CAD industrial panasonic com ac 10 500 V 1 M L1 L2 L3 U V W...

Page 8: ...C1 C2 2 1 U V W U V W CS...

Page 9: ...C3 C4 15 5...

Page 10: ...V 1 3 0 7 A 0 35 A 50 60 Hz 0 240 V 3 0 6 A 0 267 Hz 50 W Ser No P18040001G BRUSHLESS AMPLIFIER MBEU5A5AAV Made in China 20180401 1 AC100 120 V 5 AC200 240 V MBEU 5A 5 A A V V A A 5A 50 W 9A 90 W 1E...

Page 11: ...DV0P4170 SUP EK5 ER 6 DV0PM20042 3SUP HU10 ER 6 MCCB W MCCB mm2 100 V 50 130 5 A 20 A 3P 1a 0 5 AWG20 0 13 AWG26 200 V 50 130 5 A 20 A 3P 1a 0 5 AWG20 0 13 AWG26 200 V 50 130 5 A 20 A 3P 1a 0 5 AWG20...

Page 12: ...2 No 274 I 2 1 EC EN61800 5 1 EMC EN55011 EN61000 6 2 EN61000 6 4 EN61800 3 EMC II I 2 Group 1 Class A EMI Category C3 2nd environment KC 2 A 1 SCCR 5000 Arms 240 V NEC 2 A A BRUSHLESS AMPLIFIER A A...

Page 13: ...C11 C12 Pb Hg Cd Cr VI PBB PBDE SJ T11364 GB T26572 GB T26572 10 500 V 1M L1 L2 L3 U V W...

Page 14: ...MEMO C13 C14 C13 1 1 6 Panasonic Corporation 7 1 1 574 0044 81 72 871 1212 CAD URL industrial panasonic com ac c...

Page 15: ...tion continued Caution Do not use the product except for specified combination of brushless motor and brushless amplifier Cause of damages breakage Do not use store in direct sunlight Cause of damages...

Page 16: ...s or damages Stop operation by turning off the power immediately when an abnormality occurs Preventing injuries electric shock or fire Trip reset should be carried out after confirming the safety of t...

Page 17: ...t is 2 or less such as putting it in a control panel with IP 54 or higher Installation Place 1 Install the amplifier in a control panel enclosed in noncombustible material and placed indoor where the...

Page 18: ...eeded up to 10 m Personal computer Customer preparation Gear head option PC connecting cable option GV series Brushless motor GU series Brushless amplifier POWER If your PC does not have RS232 port us...

Page 19: ...the EC directive of the machinery and equipment to be incorporated Authorised representative for CE marking in the EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Ham...

Page 20: ...Torque wrench Check for loosening of bolt and tighten additionally as necessary Use environment By sight Check the ambient temperature and humidity and make sure that dirt dust or foreign substance i...

Page 21: ...0044 072 871 1212 7 1 1 574 0044 81 72 871 1212 Motor Business Unit Panasonic Corporation 7 1 1 Morofuku Daito City Osaka 574 0044 Japan Phone 81 72 871 1212 Panasonic Corporation 2018 2018 3 IMF03 P0...

Reviews: