background image

English

B7

B8

Wiring

Wiring

System configuration/ general wiring diagram

• Wiring work should be performed by qualified electric construction expart.

• Do not turn on power before finishing wiring, to avoid risk of electric shock.

Wiring equipment

 •  Recommended noise filter

Voltage

Optional part number 

(option)

Manufacturer's part 

No.

Manufacturer

Single phase 100, 200 V

DV0P4170

SUP-EK5-ER-6

OKAYA ELECTRIC 

IND. CO., LTD.

3-phase

DV0PM20042

3SUP-HU10-ER-6

•  Selection of Molded Case Circuit Breaker (MCCB), magnetic contactor, and electric wire 

(wiring within equipment).

Voltage

Capacity 

(W)

 MCCB

rated  

(

current

)

Magnetic 

contactor rated 

current 

(contact structure) 

Minimum wire size (mm

2

)

(Wiring within equipment)

Main circuit/ 

Grounding  wire    

 Control 

circuit  

Single phase 100 V  50 to 130

5 A

20 A (3P+1a)

0.5 (AWG20) 0.13 (AWG26)

Single phase 200 V  50 to 130

5 A

20 A (3P+1a)

0.5 (AWG20) 0.13 (AWG26)

3-phase  200 V 

50 to 130

5 A

20 A (3P+1a)

0.5 (AWG20) 0.13 (AWG26)

 

 Be sure to ground the grounding terminal. 

 

In wiring to power supply (outside of equipment) from MCCB, use an electric wire of 1.6 

mm diameter (2.0 mm

2

) or more both for main circuit and grounding. Must be grounded 

with resistance less than 100 Ω. Do not tighten the ground wires together, please tighten 

them individually.

Digital key pad connecting cable 

(option)

 

AC power supply

* It is the maximum length in our 

evaluation environment, 

  it does not guarantee the operation 

in customer's use environment.

It cannot be used 

simultaneously.

Digital key pad 

(option)

 

Digital display console.

It enables change of 

parameter.

Communication software PANATERM for BL

Please download from our web site

Parameter change and control state monitoring possible.

Motor extension cable 

(option)

Select if needed (up to 10 m).*

Personal computer

(Customer preparation) 

Gear head

(option)

PC connecting cable

(option)

 

 

GV series

 Brushless motor

GU series

Brushless amplifier

POWER

If your PC does not have 

RS232 port, use RS232-USB 

converter.

Noise

filter

Magnetic

contactor

MCCB

Terminal for power supply (POWER)

Part number of terminal block: 0138-7603 (DINKLE)

Terminal 

symbol

Terminal

name

Terminal explanation 

L3

Terminal for

power supply

input

Connect the terminal to commercial power supply conforming to 

voltage specification. When you use single

phase, connect the main power between L1 and L2 terminals.

L2
L1

The lower side of product is L1.

How to wiring:
Please use a single wire or rod terminal and insert as far into the connection hole.
Recommended rod terminal: TGN TC-1.25-9T(NICHIFU), Applicable wire size: AWG20 to 16.
In case of single wire: Strip length10 mm(reference): Applicable wire size: AWG20 to 14.
How to remove wiring:
Using a flathead screwdriver with a blade width of 2.6 mm, push the Wire extraction 

button of the terminal block vertically and remove the electric wire. Be careful not to apply 

excessive force at this time. (Approximately 20 N or less)
* Please check tools etc. necessary for terminal crimp on the home page of terminal 

manufacturer or contact terminal manufacturer.

* Since the strip length of the wire depends on the type of wire etc., please decide the 

optimum strip length according to the processing condition.
CAUTION: To prevent unforeseen circumstances due to poor contact etc., install and wire 

so that no stress such as pulling is applied to the terminal block through the 

cable.

[Rear view]

Connector for communications

(SER)
Connector for motor connection

(MOTOR)

Connector for control signals (I/O)

Wire extraction button

I

1 input enabled switch (SW3)

Nameplate (Displayed on the side)

Grounding terminal (     )

2 places

Terminal block for

power input (POWER)

Power supply line

connection hole

Heat sink

Summary of Contents for MINAS-BL GU series

Page 1: ...ifier MINAS BL GU series Before operating this product please be sure to read the Operating Instructions You can download the Operating Instructions from Panasonic Web Site industrial panasonic com ac...

Page 2: ...J1 J2 U V W CS...

Page 3: ...J3 J4 J3 15...

Page 4: ...P54 P 1 8 0 4 0 0 0 1 2 2 0 1 8 0 4 0 1 Model No Voltage INPUT OUTPUT Phase F L C Freq Power 200 240 V 1 3 0 7 A 0 35 A 50 60 Hz 0 240 V 3 0 6 A 0 267 Hz 50 W Ser No P18040001G BRUSHLESS AMPLIFIER MBE...

Page 5: ...200 V DV0P4170 SUP EK5 ER 6 DV0PM20042 3SUP HU10 ER 6 MCCB W MCCB mm2 100 V 50 130 5 A 20 A 3P 1a 0 5 AWG20 0 13 AWG26 200 V 50 130 5 A 20 A 3P 1a 0 5 AWG20 0 13 AWG26 200 V 50 130 5 A 20 A 3P 1a 0 5...

Page 6: ...o 274 2 1 EC 61800 5 1 EMC 55011 61000 6 2 61000 6 4 61800 3 EMC 2 Group 1 Class A EMI Category C3 2nd environment KC 2 Class A 1 SCCR 5000 Arms 240 V NEC 2 A A BRUSHLESS AMPLIFIER Class A BRUSHLESS A...

Page 7: ...J11 J12 1 1 6 0120 70 3799 TEL 072 870 3057 FAX 072 870 3120 9 00 12 00 13 00 17 00 TEL 072 870 3123 FAX 072 870 3152 9 00 12 00 13 00 17 00 CAD industrial panasonic com ac 10 500 V 1 M L1 L2 L3 U V W...

Page 8: ...C1 C2 2 1 U V W U V W CS...

Page 9: ...C3 C4 15 5...

Page 10: ...V 1 3 0 7 A 0 35 A 50 60 Hz 0 240 V 3 0 6 A 0 267 Hz 50 W Ser No P18040001G BRUSHLESS AMPLIFIER MBEU5A5AAV Made in China 20180401 1 AC100 120 V 5 AC200 240 V MBEU 5A 5 A A V V A A 5A 50 W 9A 90 W 1E...

Page 11: ...DV0P4170 SUP EK5 ER 6 DV0PM20042 3SUP HU10 ER 6 MCCB W MCCB mm2 100 V 50 130 5 A 20 A 3P 1a 0 5 AWG20 0 13 AWG26 200 V 50 130 5 A 20 A 3P 1a 0 5 AWG20 0 13 AWG26 200 V 50 130 5 A 20 A 3P 1a 0 5 AWG20...

Page 12: ...2 No 274 I 2 1 EC EN61800 5 1 EMC EN55011 EN61000 6 2 EN61000 6 4 EN61800 3 EMC II I 2 Group 1 Class A EMI Category C3 2nd environment KC 2 A 1 SCCR 5000 Arms 240 V NEC 2 A A BRUSHLESS AMPLIFIER A A...

Page 13: ...C11 C12 Pb Hg Cd Cr VI PBB PBDE SJ T11364 GB T26572 GB T26572 10 500 V 1M L1 L2 L3 U V W...

Page 14: ...MEMO C13 C14 C13 1 1 6 Panasonic Corporation 7 1 1 574 0044 81 72 871 1212 CAD URL industrial panasonic com ac c...

Page 15: ...tion continued Caution Do not use the product except for specified combination of brushless motor and brushless amplifier Cause of damages breakage Do not use store in direct sunlight Cause of damages...

Page 16: ...s or damages Stop operation by turning off the power immediately when an abnormality occurs Preventing injuries electric shock or fire Trip reset should be carried out after confirming the safety of t...

Page 17: ...t is 2 or less such as putting it in a control panel with IP 54 or higher Installation Place 1 Install the amplifier in a control panel enclosed in noncombustible material and placed indoor where the...

Page 18: ...eeded up to 10 m Personal computer Customer preparation Gear head option PC connecting cable option GV series Brushless motor GU series Brushless amplifier POWER If your PC does not have RS232 port us...

Page 19: ...the EC directive of the machinery and equipment to be incorporated Authorised representative for CE marking in the EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15 22525 Ham...

Page 20: ...Torque wrench Check for loosening of bolt and tighten additionally as necessary Use environment By sight Check the ambient temperature and humidity and make sure that dirt dust or foreign substance i...

Page 21: ...0044 072 871 1212 7 1 1 574 0044 81 72 871 1212 Motor Business Unit Panasonic Corporation 7 1 1 Morofuku Daito City Osaka 574 0044 Japan Phone 81 72 871 1212 Panasonic Corporation 2018 2018 3 IMF03 P0...

Reviews: