English
B7
B8
Wiring
Wiring
System configuration/ general wiring diagram
• Wiring work should be performed by qualified electric construction expart.
• Do not turn on power before finishing wiring, to avoid risk of electric shock.
Wiring equipment
• Recommended noise filter
Voltage
Optional part number
(option)
Manufacturer's part
No.
Manufacturer
Single phase 100, 200 V
DV0P4170
SUP-EK5-ER-6
OKAYA ELECTRIC
IND. CO., LTD.
3-phase
DV0PM20042
3SUP-HU10-ER-6
• Selection of Molded Case Circuit Breaker (MCCB), magnetic contactor, and electric wire
(wiring within equipment).
Voltage
Capacity
(W)
MCCB
rated
(
current
)
Magnetic
contactor rated
current
(contact structure)
Minimum wire size (mm
2
)
(Wiring within equipment)
Main circuit/
Grounding wire
Control
circuit
Single phase 100 V 50 to 130
5 A
20 A (3P+1a)
0.5 (AWG20) 0.13 (AWG26)
Single phase 200 V 50 to 130
5 A
20 A (3P+1a)
0.5 (AWG20) 0.13 (AWG26)
3-phase 200 V
50 to 130
5 A
20 A (3P+1a)
0.5 (AWG20) 0.13 (AWG26)
■
Be sure to ground the grounding terminal.
In wiring to power supply (outside of equipment) from MCCB, use an electric wire of 1.6
mm diameter (2.0 mm
2
) or more both for main circuit and grounding. Must be grounded
with resistance less than 100 Ω. Do not tighten the ground wires together, please tighten
them individually.
Digital key pad connecting cable
(option)
AC power supply
* It is the maximum length in our
evaluation environment,
it does not guarantee the operation
in customer's use environment.
It cannot be used
simultaneously.
Digital key pad
(option)
Digital display console.
It enables change of
parameter.
Communication software PANATERM for BL
Please download from our web site
Parameter change and control state monitoring possible.
Motor extension cable
(option)
Select if needed (up to 10 m).*
Personal computer
(Customer preparation)
Gear head
(option)
PC connecting cable
(option)
GV series
Brushless motor
GU series
Brushless amplifier
POWER
If your PC does not have
RS232 port, use RS232-USB
converter.
Noise
filter
Magnetic
contactor
MCCB
Terminal for power supply (POWER)
Part number of terminal block: 0138-7603 (DINKLE)
Terminal
symbol
Terminal
name
Terminal explanation
L3
Terminal for
power supply
input
Connect the terminal to commercial power supply conforming to
voltage specification. When you use single
phase, connect the main power between L1 and L2 terminals.
L2
L1
The lower side of product is L1.
How to wiring:
Please use a single wire or rod terminal and insert as far into the connection hole.
Recommended rod terminal: TGN TC-1.25-9T(NICHIFU), Applicable wire size: AWG20 to 16.
In case of single wire: Strip length10 mm(reference): Applicable wire size: AWG20 to 14.
How to remove wiring:
Using a flathead screwdriver with a blade width of 2.6 mm, push the Wire extraction
button of the terminal block vertically and remove the electric wire. Be careful not to apply
excessive force at this time. (Approximately 20 N or less)
* Please check tools etc. necessary for terminal crimp on the home page of terminal
manufacturer or contact terminal manufacturer.
* Since the strip length of the wire depends on the type of wire etc., please decide the
optimum strip length according to the processing condition.
CAUTION: To prevent unforeseen circumstances due to poor contact etc., install and wire
so that no stress such as pulling is applied to the terminal block through the
cable.
[Rear view]
Connector for communications
(SER)
Connector for motor connection
(MOTOR)
Connector for control signals (I/O)
Wire extraction button
I
1 input enabled switch (SW3)
Nameplate (Displayed on the side)
Grounding terminal ( )
2 places
Terminal block for
power input (POWER)
Power supply line
connection hole
Heat sink
Summary of Contents for MINAS-BL GU series
Page 2: ...J1 J2 U V W CS...
Page 3: ...J3 J4 J3 15...
Page 8: ...C1 C2 2 1 U V W U V W CS...
Page 9: ...C3 C4 15 5...
Page 13: ...C11 C12 Pb Hg Cd Cr VI PBB PBDE SJ T11364 GB T26572 GB T26572 10 500 V 1M L1 L2 L3 U V W...