21
[Before Using the Products]
Before Using
the Products
Connector
Console body
Cable
Display
(7-segment LED)
Touch panel
Display LED (6-digit)
All of LED will flash when error occurs, and switch to error display
screen.
Display LED (in 2 digits)
Parameter No. is displayed at parameter setup mode. Point No. is
displayed at teaching mode.
SHIFT Button
Press this to shift the digit for data change.
Button
Press these to change data or execute selected action of parameter.
Numerical value increases by pressing , ,
decreases by pressing .
SET Button
Press this to shift each mode which is selected by mode switching
button to EXECUTION display.
Mode Switching Button Press this to switch 7 kinds of mode.
1) Monitor mode
2) Teaching mode
• Target position settings established
by teaching
• Test operation
3) Parameter setup mode
4) EEPROM write mode
5) Normal auto-gain tuning mode
6) Auxiliary function mode
• Alarm clear
• Absolute encoder clear
7) Copy mode
• Copying of parameters from the driver to the console.
• Copying of parameters from the console to the driver.
The data for the parameters is set after the mode has been switched to the parameter setup mode. For
details on operation, refer to the instruction manual provided with the console.
Display/Touch panel
Console
Main Body
<Note>
Console is an option (Part No.: DV0P4420).