Default
1-6 (KX-TVA50), 1-24 (KX-TVA200)
Value Range
1–6 (KX-TVA50), 1–24 (KX-TVA200)
Feature Manual References
2.2.32 Message Waiting Notification—Device
Message Waiting Lamp Ports
Specifies the port numbers used for Message Waiting Notification Lamp feature. The VPS turns on the
Message Waiting Lamp of the extension using the port specified in this parameter. At least 1 port must be
specified.
Note
•
The maximum number of ports depends on the VPS model.
Default
1-6 (KX-TVA50), 1-24 (KX-TVA200)
Value Range
1–6 (KX-TVA50), 1–24 (KX-TVA200)
Feature Manual References
2.2.33 Message Waiting Notification—Lamp
Message Waiting Lamp for Every Message
If set to "Yes", the VPS will turn on the Message Waiting Lamp of the extension each time a new message is
recorded in the mailbox. This will occur even if the Message Waiting Lamp was not turned off from a previous
message. This setting is useful when the first attempt is unsuccessful. If set to "No", the VPS will turn on the
Message Waiting Lamp for the first message only. The VPS will not turn on the lamp for subsequent messages
until the subscriber has accessed the VPS to retrieve the messages stored there.
Default
Yes
Value Range
No, Yes
Feature Manual References
2.2.33 Message Waiting Notification—Lamp
Max. Digits for Callback No.
Specifies the maximum number of digits the caller can enter as a callback number. This callback number will
be displayed on beepers if "Beeper Callback No. Entry Mode" set to any value other than "Disable" (see "Beeper
Callback No. Entry Mode" in 2.1.4 Notification Parameters).
164
Programming Manual
Document Version 3.0 2010/06