![background image](http://html1.mh-extra.com/html/panasonic/kx-tde100/kx-tde100_features-manual_3482677066.webp)
Parameter
Usage
Light Pattern
Red on
Off
(All)
Used to log in to or out of all
incoming call distribution groups
to which the extension user
belongs.
After Log-out
Operation
After Log-in
Operation
•
If an ICD Group button is assigned, it also shows the log-in/log-out status of the corresponding group.
The light pattern is the same as the Log-in/Log-out button that includes the group number.
•
Wrap-up Timer
–
Two wrap-up timers can be programmed, an ICD Group member wrap-up timer and an extension
wrap-up timer. System programming selects which timer is used. When the ICD Group member
wrap-up timer is selected, the timer is only activated after calls to the extension through an ICD Group.
When the extension wrap-up timer is selected, the timer is activated after all calls to or from the
extension, including a retrieved call on hold.
–
Only calls from ICD Groups cannot be received during the wrap-up time. Other calls are received as
normal.
–
The wrap-up timer does not work for SIP extensions, ISDN extensions, or PS Ring Groups.
•
Wrap-up Button
A flexible button can be customised as the Wrap-up button. It shows the current status as follows:
Light pattern
Status
Slow red flashing
Wrap-up
Red on
Not Ready
Off
Ready (Wrap-up mode cancel)
•
When a PS in Wireless XDP Parallel Mode completes a call, neither the PS nor its wired telephone can
have Wrap-up time. (
®
1.25.5 Wireless XDP Parallel Mode)
•
Automatic Log-out
A member extension may be logged out automatically, if the Unanswered time expires a preprogrammed
number of times consecutively. The number of consecutive unanswered calls can be assigned for each
incoming call distribution group. If the extension is a member of more than one incoming call distribution
group, the unanswered number is counted across all corresponding incoming call distribution groups. It is
possible to return to log-in mode manually.
The Automatic Log-out feature does not work for extensions in an incoming call distribution group using
the Ring distribution method (
®
1.2.2.2 Group Call Distribution).
•
Log-in/Log-out Monitor
The supervisor extension can monitor and control the log-in/log-out status of the incoming call distribution
group members. (
®
1.2.2.8 Supervisory Feature)
•
Log-in/Log-out Information on SMDR
Log-in/Log-out information can be printed out on SMDR. (
®
1.26.1.1 Station Message Detail Recording
(SMDR))
PC Programming Manual References
4.9 [2-6-1] Numbering Plan—Main—Features
→
Log-in / Log-out
→
Not Ready (Manual Wrap-up) Mode On / Off
5.13 [3-5-1] Incoming Call Distribution Group—Group Settings—Miscellaneous
66
Feature Guide
1.2.2 Incoming Call Distribution Group Features
Summary of Contents for KX-TDE100
Page 16: ...16 Feature Guide Table of Contents...
Page 17: ...Section 1 Call Handling Features Feature Guide 17...
Page 95: ...User Manual References 1 2 1 Basic Calling Feature Guide 95 1 5 4 Trunk Call Features...
Page 175: ...User Manual References 1 4 2 Holding a Call Feature Guide 175 1 13 1 Call Hold...
Page 187: ...1 7 2 Answering Denying a Paging Announcement Feature Guide 187 1 15 1 Paging...
Page 389: ...Section 2 System Configuration and Administration Features Feature Guide 389...
Page 439: ...Section 3 Appendix Feature Guide 439...
Page 453: ...Index Feature Guide 453...
Page 459: ...Feature Guide 459 Notes...