With KX-T7600 Series DPT (except KX-T7665)
To a Super Hybrid Port
DPT
To a Super Hybrid Port
To SLT
2-conductor wiring cord
Connect pins "T" and "R".
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
SLT
TO MAIN UNIT
/ PABX
TO TEL
With Other DPT (except KX-T7560 and KX-T7565)
To a Super Hybrid Port
DPT
SLT
To a Super Hybrid Port
To SLT
2-conductor wiring cord
Connect pins "T" and "R".
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
TO TEL
TO EMSS or TO MAIN UNIT
Installation Manual
113
2.6.2 Parallel Connection of the Extensions