2.11
System Data Default Set
2.11.1
System Data Default Set
When the system does not operate properly after restarting, you can clear the programming
data stored in the system. The system will restart with the default setting.
First, try the operation by following step 4 in section 2.7.1
Starting the System for the First
Time. If the system still does not operate properly, please follow the procedure below.
1.
Slide the system clear switch to the "CLEAR" position.
2.
Press the reset button (with a pointed tool, if necessary).
3.
While the power indicator starts flashing (within about 10 seconds), return the system clear
switch to the "NORMAL" position. If successfully executed, the DPTs should show the
time as 0:00.
CAUTION
•
Before touching the system clear switch and reset button, put on a grounding strap.
•
After pressing the reset button, return the system clear switch to the "NORMAL" position
in step 3 while the power indicator is flashing. Otherwise, the system data will not be
cleared.
•
Even if you perform system data clear, OGM and voice message cannot be deleted. To
delete OGMs or voice messages, follow the steps described in 2.6.1 Built-in Voice Message
or 3.2.3 Recording Company Greeting Outgoing Messages in User Manual. To delete all
voice messages and OGMs at once, refer to programme [895] OGM and Voice Message
Clear.
•
Feature Reference
•
System Data Default Set
System Clear Switch
Reset Button
CLEAR
NORMAL