164
KX-MB2085CXW/KX-MB2090CXW
IC750 ( C1CB00002566 : 3.3V Single Power Supply) Pin Description
Pin No
Signal Name
Input/Output(*)
Description
1
GND
Gnd
Ground
2
VDDPLL_1.8
P
1.8V analog VDD
3
VDDA_3.3
P
3.3V analog VDD
4
RX-
I/O
Physical receive or transmit signal (- differential)
5
RX+
I/O
Physical receive or transmit signal (+ differential)
6
TX-
I/O
Physical transmit or receive signal (- differential)
7
TX+
I/O
Physical transmit or receive signal (+ differential)
8
XO
O
Crystal feedback
This pin is used only in MII mode when a 25 MHz crystal is used.
This pin is a no connect if oscillator or external clock source is used, or
if RMII mode is selected.
9
XI / REFCLK
I
Crystal / Oscillator / External Clock Input
MII Mode: 25MHz +/-50ppm (crystal, oscillator, or external clock) RMII
Mode: 50MHz +/-50ppm (oscillator, or external clock only)
10
REXT
I/O
Set physical transmit output current
Connect a 6.49K
Ω
resistor in parallel with a 100pF capacitor to ground
on this pin. See KSZ8041NL reference schematics.
11
MDIO
I/O
Management Interface (MII) Data I/O
This pin requires an external 4.7K
Ω
pull-up resistor.
12
MDC
I
Management Interface (MII) Clock Input
This pin is synchronous to the MDIO data interface.
13
RXD3 / PHYAD0
Ipu/O
MII Mode: Receive Data Output[3](2) /
Config Mode: The pull-up/pull-down value is latched as PHYADDR[0]
during power-up / reset. See “Strapping Options” section for details.
14
RXD2 / PHYAD1
Ipd/O
MII Mode: Receive Data Output[2](2) /
Config Mode: The pull-up/pull-down value is latched as PHYADDR[1]
during power-up / reset. See “Strapping Options“ section for details.
15
RXD1 /
RXD[1] /
PHYAD2
Ipd/O
MII Mode: Receive Data Output[1](2) /
RMII Mode: Receive Data Output[1](3) /
Config Mode: The pull-up/pull-down value is latched as PHYADDR[2]
during power-up / reset. See “Strapping Options“ section for details.
16
RXD0 /
RXD[0] /
DUPLEX
Ipu/O
MII Mode: Receive Data Output[0](2) /
RMII Mode: Receive Data Output[0](3) /
Config Mode: Latched as DUPLEX (register 0h, bit 8) during power-up /
reset. See “Strapping Options“ section for details.
17
VDDIO_3.3
P
3.3V digital VDD
18
RXDV /
CRSDV /
CONFIG2
Ipd/O
MII Mode: Receive Data Valid Output /
RMII Mode: Carrier Sense/Receive Data Valid Output /
Config Mode: The pull-up/pull-down value is latched as CONFIG2 dur-
ing power-up / reset. See “Strapping Options“ section for details.
19
RXC
O
MII Mode: Receive Clock Output
20
RXER /
RX_ER /
ISO
Ipd/O
MII Mode: Receive Error Output /
RMII Mode: Receive Error Output /
Config Mode: The pull-up/pull-down value is latched as ISOLATE during
power-up / reset. See “Strapping Options“ section for details.
21
INTRP
Opu
Interrupt Output: Programmable Interrupt Output
Register 1Bh is the Interrupt Control/Status Register for programming
the interrupt conditions and reading the interrupt status. Register 1Fh bit
9 sets the interrupt output to active low (default) or active high.
22
TXC
O
MII Mode: Transmit Clock Output
23
TXEN / TX_EN
I
MII Mode: Transmit Enable Input /
RMII Mode: Transmit Enable Input
24
TXD0 / TXD[0]
I
MII Mode: Transmit Data Input[0](4) /
RMII Mode: Transmit Data Input[0](5)
25
TXD1 / TXD[1]
I
MII Mode: Transmit Data Input[1](4) /
RMII Mode: Transmit Data Input[1](5)
26
TXD2
I
MII Mode: Transmit Data Input[2](4) /
27
TXD3
I
MII Mode: Transmit Data Input[3](4) /
28
COL / CONFIG0
Ipd/O
MII Mode: Collision Detect Output /
Config Mode: The pull-up/pull-down value is latched as CONFIG0 dur-
ing power-up / reset. See “Strapping Options“ section for details.
29
CRS / CONFIG1
Ipd/O
MII Mode: Carrier Sense Output /
Config Mode: The pull-up/pull-down value is latched as CONFIG1 dur-
ing power-up / reset. See “Strapping Options“ section for details.
Summary of Contents for KX-MB2085CXW
Page 44: ...44 KX MB2085CXW KX MB2090CXW 6 11 LSU Laser Scanning Unit Section ...
Page 45: ...45 KX MB2085CXW KX MB2090CXW ...
Page 53: ...53 KX MB2085CXW KX MB2090CXW 6 12 9 2 Drum Detection ...
Page 60: ...60 KX MB2085CXW KX MB2090CXW ...
Page 80: ...80 KX MB2085CXW KX MB2090CXW KX MB2090 ...
Page 81: ...81 KX MB2085CXW KX MB2090CXW Note The above values are the default values ...
Page 112: ...112 KX MB2085CXW KX MB2090CXW 12 3 7 6 Light Print CROSS REFERENCE High Voltage Section P 152 ...
Page 114: ...114 KX MB2085CXW KX MB2090CXW 12 3 8 2 The Recording Paper Is Waved or Wrinkled ...
Page 115: ...115 KX MB2085CXW KX MB2090CXW 12 3 8 3 Skew ...
Page 117: ...117 KX MB2085CXW KX MB2090CXW 12 3 8 5 The Recording Paper Jam ...
Page 126: ...126 KX MB2085CXW KX MB2090CXW ...
Page 128: ...128 KX MB2085CXW KX MB2090CXW ...
Page 129: ...129 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 130: ...130 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 131: ...131 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 132: ...132 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 133: ...133 KX MB2085CXW KX MB2090CXW ...
Page 134: ...134 KX MB2085CXW KX MB2090CXW ...
Page 135: ...135 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 144: ...144 KX MB2085CXW KX MB2090CXW 12 3 15 Motor Section 12 3 15 1 Engine Motor ...
Page 148: ...148 KX MB2085CXW KX MB2090CXW 12 3 17 CIS Control Section ...
Page 149: ...149 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 151: ...151 KX MB2085CXW KX MB2090CXW ...
Page 152: ...152 KX MB2085CXW KX MB2090CXW 12 3 19 High Voltage Section 1 Main ...
Page 153: ...153 KX MB2085CXW KX MB2090CXW 2 CHG GRID ...
Page 154: ...154 KX MB2085CXW KX MB2090CXW 3 TRA ...
Page 155: ...155 KX MB2085CXW KX MB2090CXW 3 DEV DC ...
Page 156: ...156 KX MB2085CXW KX MB2090CXW TRA ...
Page 158: ...158 KX MB2085CXW KX MB2090CXW 2 Confirmation of the main unit ...
Page 160: ...160 KX MB2085CXW KX MB2090CXW Waveform of normal operation ...
Page 162: ...162 KX MB2085CXW KX MB2090CXW 2 When 100Base TX enabled deviced is connected ...
Page 163: ...163 KX MB2085CXW KX MB2090CXW 3 When 10Base T enabled device is connected ...
Page 168: ...168 KX MB2085CXW KX MB2090CXW 12 3 23 2 Troubleshooting Flow Chart ...
Page 171: ...171 KX MB2085CXW KX MB2090CXW 13 Service Fixture Tools ...
Page 173: ...173 KX MB2085CXW KX MB2090CXW 14 1 Bottom Section 14 2 Left Side Section ...
Page 174: ...174 KX MB2085CXW KX MB2090CXW 14 3 Operation Panel Section 14 4 Open Top Cover ...
Page 175: ...175 KX MB2085CXW KX MB2090CXW 14 5 Remove Operation Panel 14 6 Remove Operation Board ...
Page 176: ...176 KX MB2085CXW KX MB2090CXW 14 7 Remove Main Board ...
Page 177: ...177 KX MB2085CXW KX MB2090CXW 14 8 Remove Gear Chassis Section ...
Page 178: ...178 KX MB2085CXW KX MB2090CXW 14 9 Remove Right Cover 14 10 Remove Right Cassette Guide ...
Page 179: ...179 KX MB2085CXW KX MB2090CXW 14 11 Remove Bottom Plate 14 12 Remove Laser Unit ...
Page 180: ...180 KX MB2085CXW KX MB2090CXW 14 13 Remove Pick up Roller ...
Page 181: ...181 KX MB2085CXW KX MB2090CXW 14 14 Remove Low Voltage Power Board 14 15 Remove Mirror ...
Page 200: ...200 KX MB2085CXW KX MB2090CXW 15 6 1 NG Example ...
Page 201: ...201 KX MB2085CXW KX MB2090CXW 15 7 Test Chart 15 7 1 ITU T No 1 Test Chart ...
Page 202: ...202 KX MB2085CXW KX MB2090CXW 15 7 2 ITU T No 2 Test Chart ...
Page 257: ...Information The extract from an Operating Instructions ...