General Block Diagram
MAIN UNIT
SOC (IC300)
This custom IC is used for general MFP operations.
ROM (IC402)
This 8MB FLASH ROM contains all of the program instructions on the unit operations.
And support the backup of user setting and FAX receive data.
SYNCHRONOUS DYNAMIC RAM (IC400)
This 256Mbit SDRAM is used for CPU work and receiving memory and page memory.
POWER SUPPLY
DC-DC converters generate 3.3V and 1.2V for system power.
Regurator generates 5V for peripheral devices.
TEL/FAX I/F
Composed of ITS circuit and NCU circuit.
Analog DAA (Direct Access Arrangement) and two AFE (Analog Front End) IC control Telephone line, Speaker, and Hand-
set.
READ SECTION
CIS Unit to read transmitted documents.
CIS Unit is connected to FLATBED transit Unit.
Scan data is converted by AFE(IC503).
MOTOR
This model has 1 DC motor and 2 stepping motors.
IC300 drives the DC motor for printing.
IC502 drives the stepping motor for Auto Document Feeder motor and CIS carriage.
LSU
Forms the images on the OPC DRUM by rotating polygon motor and reflecting the laser beam against polygon.
SENSORS
Composed of 2 switches and 5 sensors.
POWER SUPPLY BOARD
Su24V and +7V to the Main unit and controls the Heat Lamp.
HIGH VOLTAGE POWER SUPPLY BOARD
Supplies bias need for the printing operation: bias of the DRUM, Developing and Transcription.
FIXING UNIT
Composed heat lamp, thermistor and thermostats.
1)
CPU
ARM9 operating at 250MHz.
2)
SDRAM Controller
Controls SDRAM Memory.
3)
USB Controller with PHY
Apply to USB2.0 HS
4)
Scanner I/F
Controls the CIS and AFE, and process the scan images.
5)
LSU I/F
Controls the polygon motor and outputs the VIDEO signal to LSU.
6)
MOTOR I/F
Controls the DC motor and Stepping Motor.
7)
FAN I/F
Controls FAN MOTOR and detect the rotation of FAN MOTOR.
8)
OPERATION PANEL I/F
Serial interface with Operation Panel.
9)
SENSOR I/F
Detects the sensor signal.
10) I/O PORT
I/O Port Interface.
11) A/D, D/A converter
Sends beep tones, etc.
Convert the analog signal to the digital signal.
12) RTC
Real time clock.
13) MODEM
Performs the modulation and the demodulation for FAX communication.
14) Analog Front End I/F
Controls the DAA device for TEL/FAX function.
15) LAN Controller
Ethernet Control. (KX-MB2090 ONLY)
Summary of Contents for KX-MB2085CXW
Page 44: ...44 KX MB2085CXW KX MB2090CXW 6 11 LSU Laser Scanning Unit Section ...
Page 45: ...45 KX MB2085CXW KX MB2090CXW ...
Page 53: ...53 KX MB2085CXW KX MB2090CXW 6 12 9 2 Drum Detection ...
Page 60: ...60 KX MB2085CXW KX MB2090CXW ...
Page 80: ...80 KX MB2085CXW KX MB2090CXW KX MB2090 ...
Page 81: ...81 KX MB2085CXW KX MB2090CXW Note The above values are the default values ...
Page 112: ...112 KX MB2085CXW KX MB2090CXW 12 3 7 6 Light Print CROSS REFERENCE High Voltage Section P 152 ...
Page 114: ...114 KX MB2085CXW KX MB2090CXW 12 3 8 2 The Recording Paper Is Waved or Wrinkled ...
Page 115: ...115 KX MB2085CXW KX MB2090CXW 12 3 8 3 Skew ...
Page 117: ...117 KX MB2085CXW KX MB2090CXW 12 3 8 5 The Recording Paper Jam ...
Page 126: ...126 KX MB2085CXW KX MB2090CXW ...
Page 128: ...128 KX MB2085CXW KX MB2090CXW ...
Page 129: ...129 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 130: ...130 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 131: ...131 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 132: ...132 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 133: ...133 KX MB2085CXW KX MB2090CXW ...
Page 134: ...134 KX MB2085CXW KX MB2090CXW ...
Page 135: ...135 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 144: ...144 KX MB2085CXW KX MB2090CXW 12 3 15 Motor Section 12 3 15 1 Engine Motor ...
Page 148: ...148 KX MB2085CXW KX MB2090CXW 12 3 17 CIS Control Section ...
Page 149: ...149 KX MB2085CXW KX MB2090CXW CROSS REFERENCE Test Functions P 70 ...
Page 151: ...151 KX MB2085CXW KX MB2090CXW ...
Page 152: ...152 KX MB2085CXW KX MB2090CXW 12 3 19 High Voltage Section 1 Main ...
Page 153: ...153 KX MB2085CXW KX MB2090CXW 2 CHG GRID ...
Page 154: ...154 KX MB2085CXW KX MB2090CXW 3 TRA ...
Page 155: ...155 KX MB2085CXW KX MB2090CXW 3 DEV DC ...
Page 156: ...156 KX MB2085CXW KX MB2090CXW TRA ...
Page 158: ...158 KX MB2085CXW KX MB2090CXW 2 Confirmation of the main unit ...
Page 160: ...160 KX MB2085CXW KX MB2090CXW Waveform of normal operation ...
Page 162: ...162 KX MB2085CXW KX MB2090CXW 2 When 100Base TX enabled deviced is connected ...
Page 163: ...163 KX MB2085CXW KX MB2090CXW 3 When 10Base T enabled device is connected ...
Page 168: ...168 KX MB2085CXW KX MB2090CXW 12 3 23 2 Troubleshooting Flow Chart ...
Page 171: ...171 KX MB2085CXW KX MB2090CXW 13 Service Fixture Tools ...
Page 173: ...173 KX MB2085CXW KX MB2090CXW 14 1 Bottom Section 14 2 Left Side Section ...
Page 174: ...174 KX MB2085CXW KX MB2090CXW 14 3 Operation Panel Section 14 4 Open Top Cover ...
Page 175: ...175 KX MB2085CXW KX MB2090CXW 14 5 Remove Operation Panel 14 6 Remove Operation Board ...
Page 176: ...176 KX MB2085CXW KX MB2090CXW 14 7 Remove Main Board ...
Page 177: ...177 KX MB2085CXW KX MB2090CXW 14 8 Remove Gear Chassis Section ...
Page 178: ...178 KX MB2085CXW KX MB2090CXW 14 9 Remove Right Cover 14 10 Remove Right Cassette Guide ...
Page 179: ...179 KX MB2085CXW KX MB2090CXW 14 11 Remove Bottom Plate 14 12 Remove Laser Unit ...
Page 180: ...180 KX MB2085CXW KX MB2090CXW 14 13 Remove Pick up Roller ...
Page 181: ...181 KX MB2085CXW KX MB2090CXW 14 14 Remove Low Voltage Power Board 14 15 Remove Mirror ...
Page 200: ...200 KX MB2085CXW KX MB2090CXW 15 6 1 NG Example ...
Page 201: ...201 KX MB2085CXW KX MB2090CXW 15 7 Test Chart 15 7 1 ITU T No 1 Test Chart ...
Page 202: ...202 KX MB2085CXW KX MB2090CXW 15 7 2 ITU T No 2 Test Chart ...
Page 257: ...Information The extract from an Operating Instructions ...