9. Help
94
9.8 Cleaning the
document feeder rollers
Clean the rollers when the document or
recording paper frequently misfeeds.
1
Turn the power switch OFF.
2
Hold the ADF cover (
1
) firmly and lift it to
open the upper part (
2
) of the ADF cover,
then open the whole of the ADF cover.
3
Clean the document feeder rollers (
1
) with a
cloth moistened with isopropyl rubbing
alcohol, and let all parts dry thoroughly.
L
Clean the rollers in the direction of the
arrow to avoid the discharge brush (
2
)
from being pulled.
4
Close the ADF cover.
5
Turn the power switch ON.
2
1
1
2
FLB853EX-PFQX2373ZB-en.book Page 94 Tuesday, February 21, 2006 7:09 PM