FUNCTION SETTINGS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
5-75
■
Number of Connected Controllers Check (Master Unit Only)
This function checks the number of controllers that are connected, and outputs an error if the
number has changed.
An error occurs if the number of controllers increases or decreases as compared to the number
of connected controllers at the time the check function was turned ON.
If you need to change the number of connected controllers, turn OFF the number of connected
controllers check function, change the number of controllers, and then turn the check function
back ON.
Setting method
●
Number of connected controllers check
Long-press for 2 seconds
: Select
: Finalize
CALC: Only appears on master unit
Setting item
Set values
Default value
Number of connected controllers
check (CON.CHK)
Check OFF (OFF)
Check ON (ON)
OFF
<Reference>
The number of connected controllers check can only be turned ON at the master unit.