BASIC OPERATION
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
4-12
<1-point teaching>
1.
Long-press the LEFT key for 2 seconds. (The number of lit increments in the circle meter
increases.)
Long-press for 2 seconds
2.
"SET1" appears in the digital display / SUB (green), and the digital display / MAIN (white)
blinks.
3.
The master workpiece is measured. To acquire the master workpiece judgment value,
press the ENTER key.
4.
When teaching is completed, "GOOD" appears in the digital display / MAIN (white), and the
HIGH set value and LOW set value are finalized. You then return automatically to the base
screen.