FUNCTION SETTINGS
© Panasonic Industrial Devices SUNX Co., Ltd. 2019
5-14
<Reference>
● Set the hysteresis to a value that is smaller than the difference between the HIGH set value and
the LOW set value. If the hysteresis is set to a value that is larger than the difference between
the HIGH set value and the LOW set value, a GO judgment will not be output.
Hysteresis
Hysteresis
HIGH set value
LOW set value
HIGH
GO
LOW
Judgment value
●
Even when a hysteresis is set, always set a HIGH set value that is higher than the LOW set
value. If the LOW set value is higher than the HIGH set value, a GO judgment will not be output.
Judgment value
HIGH set value
LOW set value
HIGH
GO
LOW
Hysteresis
Hysteresis
Setting method
Long-press for 2 seconds
: Move through digits
: Change value
Finalize
CALC: Only appears on master unit
Setting item
Setting range
Default value
Hysteresis (HYSTER)
0 to 199.9999 (mm)
0.0030