Peak to Peak Hold / 2 (Trigger mode: Hold)
With respect to normal measured values (NORM.V) during any sampling interval, half the differ
-
ence between the peak value and the bottom value is held as the judgment value (JUDGE.V).
Timing chart
0
6
Normal measured value
(
NORM.V
)
*
Judgment value
(
JUDGE.V
)
Indeterminate state is held.
Outputs OUT1 / OUT2 / OUT3 according to output setting.
OFF
HIGH set value
LOW set value
ON
ON
OFF
TRIG
indicator
HOLD
indicator
1.
Based on the peak to peak / 2 setting (peak value to bottom value), the judgment value
(JUDGE.V) is gradually updated from 0.
2.
The judgment value (JUDGE.V) is held while the external trigger input is ON.
3.
If the reset input turns ON while the external trigger input is OFF, an indeterminate state oc-
curs during the response time. All outputs remain OFF during an indeterminate state.
4.
After the response time elapses, the indeterminate state is released.
5.
If the reset input turns ON while the external trigger input is ON, the indeterminate state is
held until the external trigger input turns OFF.
6.
Judgment output outputs the judgment result based on the output setting.
* When the calculation function is used, calculation value “CALC” is shown instead of normal
measured value (NORM.V).
Summary of Contents for HG-S Series
Page 2: ... Panasonic Industrial Devices SUNX Co Ltd 2019 2 MEMO ...
Page 7: ...1 1 Chapter 1 INTRODUCTION 1 1 Safety Cautions 1 2 1 2 Safety Information 1 2 ...
Page 44: ... Panasonic Industrial Devices SUNX Co Ltd 2019 3 24 MEMO ...
Page 72: ... Panasonic Industrial Devices SUNX Co Ltd 2019 4 28 MEMO ...
Page 75: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 3 MEMO ...
Page 174: ... Panasonic Industrial Devices SUNX Co Ltd 2019 5 102 MEMO ...
Page 175: ...6 1 Chapter 6 SPECIFICATIONS 6 1 Specifications 6 2 6 2 Dimensions 6 7 ...
Page 188: ... Panasonic Industrial Devices SUNX Co Ltd 2019 6 14 MEMO ...
Page 198: ... MEMO ...