8
http://panasonic-electric-works.net/sunx
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
Europe Headquarter: Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
Phone: +49-8024-648-0
US Headquarter: Panasonic Electric Works Corporation of America
629 Central Avenue, New Providence, New Jersey 07974, USA
Phone: +1-908-464-3550
17
Specifications
Type
standard type
2-output type
Cable type
Model number
NPN output
FX-501
FX-502
FX-505-C2
PNP output
FX-501P
FX-502P
FX-505P-C2
Supply voltage
12 to 24V DC % (+10% / ‑10%), ripple P‑P10% or less
Power consumption
Normal operation: 960mW or less (current consumption 40mA or less at 24V supply voltage)
Eco mode: 680mW or less (current consumption 28mA or less at 24V supply voltage)
Output (
FX-502□
and
FX-505□-C2
only:
output 1, output 2)
nPn open-collector transistor
●
Maximum sink current (see note 2):
FX-501
: 100mA
FX-502, FX-505
: 50mA
●
Applied voltage: 30V DC or less between sensing output and 0V
●
Residual voltage: 2V or less (see note 3) at maximum sink current
PnP open-collector transistor
●
Maximum source current (see note 2):
FX-501P
: 100mA
FX-502P, FX-505P
: 50mA
●
Applied voltage: 30V DC or less between sensing output and +V
●
Residual voltage: 2V or less (see note 3) at maximum source current
Number of outputs
1
2
Output operation
Switchable either Light‑ON or Dark‑ON
Short‑circuit protection
Incorporated
Response time
H-SP: 25μs or less, FAST: 60μs or less, STD: 250μs or less, LONG: 2ms or less, U-LG: 4ms or less, HYPR: 24ms or less
Analog output (
FX-505□-C2
only)
—
—
●
Output current: approx. 4 to 20mA
(display in H‑SP, FAST, STD: 0
to 4,000, display in LONG: 0 to
8,000 (see note 4))
●
Response time: 2ms or less
●
Zero point: within 4mA ±1%F.S.
●
Span: within 16mA ±5%F.S.
●
Linearity: within ±3%F.S.
● Load resistance: 0 to 250Ω
External input (switchable with output 2 for
FX-502□
)
—
signal condition of nPn non-contact input:
●
High: +8V to +V DC or Open
●
Low: 0 to +1.2V DC (at 0.5mA source current)
● Input impedance: Approx. 10kΩ
signal condition of PnP non-contact input:
●
High: +4V to +V DC (at 3mA sink current)
●
Low: 0 to +0.6V DC or Open
● Input impedance: Approx. 10kΩ
Protection
IP40 (IEC)
Ambient temperature
‑10 to +55°C (no dew condensation or icing allowed)
●
For 4 to 7 units mounted in cascade: ‑10 to +50°C
●
For 8 to 12 units mounted in cascade: ‑10 to +45°C)
Storage: ‑20 to +70°C
Ambient humidity
35 to 85% RH, Storage: 35 to 85% RH
Material
Enclosure: polycarbonate, switch: TPEE, protective cover: polycarbonate
Cable
Cables are not supplied with the product. Select cables from the table below,
0.2 mm
2
6‑core cab tire cable, 2m
Weight (main body only)
Approx. 15g
Approx. 60g
Accessory
FX-MB1 (Amplifier protection seal): 1 set.
notes:
1.
Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23°C.
2.
FX-501
□
: 50mA max. if 5 or more series connection types are connected together (25mA for
FX-502
□
)
3. Only if you are using the quick‑connection cable (optional, cable length 5m).
4.
If the digital display has been adjusted manually, the figures displayed may be outside the range.
Cable
Amplifier
Cable length 1m
Cable length 2m
Cable length 5m
Main cable
Sub cable
Main cable
Sub cable
Main cable
Sub cable
FX-501
□
CN‑73‑C1
CN‑71‑C1
CN‑73‑C2
CN‑71‑C2
CN‑73‑C5
CN‑71‑C5
FX-502
□
CN‑74‑C1
CN‑72‑C1
CN‑74‑C2
CN‑72‑C2
CN‑74‑C5
CN‑72‑C5
*
You can extend the cable up to 100m max. with 0.3mm
2
or more cable. However, in order to reduce noise, make the wiring as short as possible.