6
12
PRO mode (PRO)
●
When the mode indicator PRO (yellow) is ON, you can scroll through
the PRO menu (Pro1 to Pro7) and make advanced settings.
●
For the setting procedure, refer to the “PRO MODE OPERATION
MANUAL” (only available in English).
● Note that FX-502□ has two additional setting items in Pro3 and Pro4.
<PRO1>
<PRO3>
<PRO2>
<PRO5>
Code setting
<PRO6>
Reset setting
<PRO4>
<PRO7>
+, -
SET
SET
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
+, -
SET
SET
SET
SET
+, -
SET
Shift amount setting
Timer setting
Response time setting
Hysteresis setting
Emission power setting
Timer range setting
Teaching lock setting
Setting items in digital display setting
Setting of digital display turning
Time period hold setting
Data bank loading setting
Back up setting
Data bank saving setting
ECO setting
Communication protocol setting
Display adjustment setting
Setting of threshold value tracking
Copy lock setting
Copy action setting
CUSTOM setting
Interference prevention setting
Sensing output setting
Copy setting
External input setting
(only for FX-502□
and FX-505□)
Logic operation setting
Input / output setting
(only for FX-502□)
13
optical communication
It is possible to use optical communication for the following functions.
●
Data bank loading / saving (use
FX-502□
or
FX-505□-C2
as the main
amplifier)
●
Copy settings
notes on mounting
Communication
is performed via
the communica‑
tion window of the
amplifier (marked
with an arrow).
Communication direction
1
2
For optical com‑
munication to
work, you need to
cascade the sub
amplifiers (
2
) to
the right of the
main amplifier
(
1
).
● Make sure to mount the amplifiers closely when the interference pre
‑
vention function is controlled by optical communication. For the setting
procedure, refer to the “PRO MODE OPERATION MANUAL” (only
available in English).
● When you cascade this product together with other products (e.g. fiber
sensor amplifiers, pressure sensor controllers, etc.), install the prod
‑
ucts so that they are in order of group A, B, D and C as shown in the
figure below. This product is included in group D. Within each group,
identical models should be mounted next to each other.
Communication direction
Group
A
Group
B
Group
D
Group
C
Group Model number
A
FX-301□
(conventional version unit)
FX-301B□/G□/H□, LS-401□
B
FX-301□
(modified version unit)
FX-305□, FX-301□-C1
C
LS-403□
, DPS series
D
FX-500
series
●
If products are mounted between different groups, cover the com‑
munication window of each product with the amplifier protection seal
FX-MB1
(optional).
●
If you use copy setting for a cascade of different products from the FX‑
500 series, each product will only accept the settings that it supports
and ignore settings for unsupported functions.
notes on optical communication
● Optical communication is not possible if an amplifier is in one of the
following states:
‑ The copy lock has been activated (setting
).
‑ The digital display is blinking.
‑
The external input setting of the main amplifier is set to
(only for databank loading / saving).
● When the communication protocol of a sub amplifier is set to halt com
‑
munication (setting
), it is not possible to communicate with
any of the sub amplifiers mounted to the right of said sub amplifier.
14
Interference prevention function
There are 2 options available for interference prevention:
●
Interference prevention by optical communication (
, default).
●
Interference prevention by different emitting frequency.
For the setting procedure, refer to the “PRO MODE OPERATION MANUAL”
(only available in English).
Interference can be prevented only for a limited number of amplifiers when
you have selected the default setting
(optical communication). The
number of amplifiers depends on the response time you have selected, see
table below.
H-sP
≤25μs
Fast
≤60μs
stD
≤250μs
LONG
≤2ms
U-LG
≤4ms
HYPr
≤24ms
—
2
4
8
8
12
If you have mounted more amplifiers than the interference prevention func
‑