background image

1

InstructIon Manual

Digital Fiber Sensor Amplifier

FX-501□, FX-502□, FX-505□-C2

 Series

Thank you for purchasing products from Panasonic Electric Works SUNX 
Co., Ltd. Please read this Instruction Manual carefully and thoroughly for 
the correct and optimum use of this product. Kindly keep this manual in a 
convenient place for quick reference.

WARNING

 

Never use this product as a sensing device for personnel protection.

 

In case of using sensing devices for personnel protection, use prod‑
ucts which meet laws and standards, such as OSHA, ANSI or IEC 
etc., for personnel protection applicable in each region or country.

1

compliance with standards

This product complies with the following standards and 
regulations.

 

For the EU: EMC Directive 2004/108/EC

 

For the US and Canada:  
ANSI/UL60947‑5‑2, CAN/CSA C22.2 No.14

 

For Korea: S1‑G‑1‑2009, S2‑W‑5‑2009

In case you require a ul listing mark or c-ul 

listing mark, use a class 2 power supply unit.

2

Part description

FX-501

1

2

3

4

5

6

7

8

9

1

Operation indicator for sensing output (orange)

2

Digital display (green / red)

3

UP key (+)

Functions:

 

Teach

 

Fine adjustment of the threshold value

 

Select settings

4

DOWN key (–)

5

MODE key

Functions:

 

Select modes

 

Cancel

6

SET key

Functions:

 

Teach

 

Save selected settings

7

Mode indicator PRO mode (yellow), see page 6

8

Mode indicator CUST (custom) mode (yellow), see page 5

9

Mode indicator L /D (Light‑ON / Dark‑ON) mode (yellow)

FX-502□ and FX-505□-C2

1

2

3

4

5

6

7

8

9

0

1, 

Sensing output 1 (lit if output is active)

 

Yellow: Sensing output is selected

 

Orange: Sensing output is operating

2

Sensing output 2 (lit if output is active)

 

Yellow: Sensing output is selected

 

Orange: Sensing output is operating

3

Digital display (green / red)

4

UP key (+)

Functions:

 

Teach

 

Fine adjustment of the threshold value

 

Select settings

5

DOWN key (–)

6

MODE key

Functions:

 

Select modes

 

Cancel

7

SET key

Functions:

 

Teach

 

● Confirm selected settings

8

Mode indicator PRO mode (yellow)

9

Mode indicator CUST (custom) mode (yellow)

0

Mode indicator L /D (Light‑ON / Dark‑ON) mode (yellow)

To toggle the key lock function ON/OFF, press the SET and the 

MODE key together for 3 seconds.

3

Mounting

Installation to a DIn rail

1.  Attach the railing on the rear of the ampli‑

fier to the DIN rail.

2. 

Push the amplifier in the direction of the 

arrow as illustrated so that it attaches 
securely.

1. 

2. 

removal from a DIn rail

1. 

Push the amplifier forward.

2. 

Lift the front part of the amplifier up.

1. 

2. 

Connecting the fiber cable

The attachments to the fiber cables need to be fitted BEFORE 

you insert the fibers into the amplifier. For details, refer to the 

instruction manual enclosed with the fibers.

1. 

Snap the fiber lock lever 

1

 down as 

far as it will go.

2. 

Insert the fiber cables slowly into the 

inlets until they stop (see note).

3. 

Return the fiber lock lever to the 

original position.

2. 

1. 

3. 

With the coaxial reflective type fiber, such as FD-G4 or FD-FM2, 

insert the single core fiber cable into the inlet for the emitter 

2

 

(inlet on the amplifier is labeled “P”) and the multi-core fiber 

cable into the inlet for the receiver 

3

. If they are inserted the 

wrong way round, the sensing performance will deteriorate.

Summary of Contents for FX-501 Series

Page 1: ...tput is active Yellow Sensing output is selected Orange Sensing output is operating 2 Sensing output 2 lit if output is active Yellow Sensing output is selected Orange Sensing output is operating 3 Digital display green red 4 UP key Functions Teach Fine adjustment of the threshold value Select settings 5 DOWN key 6 MODE key Functions Select modes Cancel 7 SET key Functions Teach Confirm selected s...

Page 2: ...e 5 I O circuit diagrams FX 501 NPN type 12 24V DC 10 15 Main circuit Brown V see note Load Black sensing output Blue 0V see note FX 501P PNP type 12 to 24V DC 10 15 Main circuit Brown V see note Load Black sensing output Blue 0V see note The quick connection sub cable does not have V brown and 0V blue The power is supplied from the connector of the main cable Terminal arrangement 1 2 3 Terminal n...

Page 3: ...mmended depends on the sensor type and whether the sensing object is present or not present or moving Sensing condition Recommended teaching method Sensing object is present and easily detectable 2 point teaching Sensing object is very small Other objects are in the background Limit teaching Production line cannot be stopped and sensing object is moving Auto teaching All teaching methods are avail...

Page 4: ...SL P 1 2_SL P 2 1_SL P 1 2_SL P 2 1_SL P 1 Teaching point 1 serving as the lower threshold value 2_SL P 2 Teaching point 2 serving as the upper threshold value 1 Press the SET key when the first sensing object is present 2 Press the SET key again when the second sensing object is present Display when stable sensing is possible Display when stable sensing is not possible If you select a value excee...

Page 5: ... shows Activating the key lock function 1 Press the SET and the MODE key together for 3 seconds or longer The digital display changes to show the key lock function has been activated Then the digital display returns to show the current values Deactivating the key lock function 1 Press the SET and the MODE key together for 3 seconds or longer The digital display changes to show the key lock functio...

Page 6: ... sensor amplifiers pressure sensor controllers etc install the prod ucts so that they are in order of group A B D and C as shown in the figure below This product is included in group D Within each group identical models should be mounted next to each other Communication direction Group A Group B Group D Group C Group Model number A FX 301 conventional version unit FX 301B G H LS 401 B FX 301 modif...

Page 7: ... gap be tween the master communication unit and the subordinated amplifiers 16 Cautions This product has been developed produced for industrial use only This product is suitable for indoor use only Make sure to add or remove amplifiers with the power OFF If you apply a voltage exceeding the rated range or if an AC power supply is connected directly the product may get burnt or damaged Shortcircuit...

Page 8: ... SP FAST STD 0 to 4 000 display in LONG 0 to 8 000 see note 4 Response time 2ms or less Zero point within 4mA 1 F S Span within 16mA 5 F S Linearity within 3 F S Load resistance 0 to 250Ω External input switchable with output 2 for FX 502 Signal condition of NPN non contact input High 8V to V DC or Open Low 0 to 1 2V DC at 0 5mA source current Input impedance Approx 10kΩ Signal condition of PNP no...