157
Fuser Error Detection
200
180
170
160
150
70
25
14
( C)
165
155
OFF
Approx. 30 sec
Time
E26 will be logged.
E24 will be logged if Thermistor detects 180 C
for more than 3 sec. (Thermostat will open.)
E23 will be logged if Thermistor
detects 175 C or higher for 5 min.
after Fuser Lamp is turned Off.
E24 will be logged if
Thermistor detects less
than 140 C for 3 sec during
the print process.
E22 will be logged when
temperature does not rise.
E25 will be logged when
temperature does not go up
at low temperature
environment.
Fuser Roller Temperature