122
4.6.2.
Poor Transmitted Copy Quality
START
Yes
Make a copy.
No
No
Yes
Is the printed copy normal?
Perform a transmission test
to a reference fax unit.
Is the LED Array lit?
Does CN1, pin 1 on the
SC PCB measure
+24 VDC?
Yes
No
Yes
No
Are CN7 (SC PCB)
and CN30 (CCD PCB)
connected properly?
Connect them correctly.
Replace the LVPS.
Does nLEDON go Low
when the scan starts?
Check CN1 on the SC
PCB and the LED
harness.
Does the problem still
occur?
Replace the LED Array.
The receiving unit may be
defective.
1. Replace the Scanner
Block.
2. Replace the SC PCB.
Replace the SC PCB.
Is the transmitted copy
normal?
No
Yes
No
No
1. Check CN18 (SC PCB)
and CN28 and 29 (MJR PCB).
2. Check the telephone line cable.
Replace if necessary.
Does poor transmitted copy
appear when transmitting to
a specific receiver?
Telephone line quality is
poor.
END
Yes
Yes
Yes
Summary of Contents for Facsimile UF-590
Page 17: ...17 1 4 Control Panel For USA and Canada UF 790 UF 780 790 780 ...
Page 18: ...18 For Other Destinations UF 590 UF 580 ...
Page 27: ...27 10 Remove 2 P6A Bushings 316 11 Remove the Eject Roller 303 10 11 ...
Page 33: ...33 11 Remove 2 Screws 4N 12 Remove the Paper Feed Rollers 518 11 12 ...
Page 294: ...294 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 2 4 Model UF 580 590 780 790 ...
Page 295: ...295 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 3 4 Model UF 580 590 780 790 ...
Page 296: ...296 4 3 2 1 D C B A 1 2 3 4 Drawing Name HVPS 4 4 Model UF 580 590 780 790 ...
Page 297: ...297 4 3 2 1 D C B A 1 2 3 4 Drawing Name LVPS 1 1 Model UF 580 590 780 790 ...
Page 298: ...DZZSM00158 ...